CJ1W-AD041-V1

Analog input unit, 4 x inputs 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA, resolution 1:4000 / 8000. screw terminal

Specifications

I/O system    CJ I/O Bus

Expansion unit type    Special I/O Unit

Type of module    Analog I/O

Number of analog inputs    4

Temperature input type    None

Linear analog input type    -10 to 10 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, 4 to 20 mA

Resolution of the analog inputs    13 Bit

Input circuit type    Standard

Number of analog outputs    0

Linear analog output type    None

Resolution of the analog outputs    0 Bit

Conversion time    4000 ms/unit

I/O connection type    Screw

Number of I/O connectors    1

Detachable I/O terminal block

Suitable for safety functions

Product Height (unpacked)    90 mm

Product Width (unpacked)    31 mm

Product Depth (unpacked)    89 mm

Product Weight (unpacked)    150 g

The following example shows EM bank 2 converted to file memory.

EM File Memory setting: 1

(EM file memory enabled)

Peripheral Port Settings

EM Starting Bank setting: 2

Converted

EM file memory

These settings are effective only when pin 4 of the DIP switch on the front of

the CPU Unit is ON.

The default settings for the peripheral port are: host link mode, 1 start bit, 7

data bits, even parity, 2 stop bits, and a baud rate of 9.600 bps. Set the periph

eral port settings in the PLC Setup when you need to change these settings.

Note When pin 4 of the DIP switch on the front of the CPU Unit is OFF, the CPU

Unit automatically detects the communications parameters of a connected

Programming Device (including Programming Consoles). Those automatically

detected parameters are not stored in the PLC Setup.

S-073N   3BHB009884R0021 Frame ABB Semiconductor thyristor
S-093H 3BHB009885R0004 Semiconductor   thyristor ABB
S-113H 3BHB018008R0003 Semiconductor   thyristor ABB
PR6423/000-031-CN+CON021 Cover vibration   sensor EPRO
USI-0002 HONEYWELL Universal Safety   Interface
AKM33E-ANCNR-00 KOLLMORGEN AKMSeries   Servo Motor
CC-GAIX21 HONEYWELL Universal Marshalling   Solution for Safety Systems
RAUMASTC-2 AQUAMASTER Digital stepping   motor and driver
SR511 3BSE000863R0001 ABB SR511 Regulator   24V/5V
MTL4549C MTL ISOLATING DRIVER
SCE905AN-002-01 High Performance Digital   Servo Drive PACIFIC
VS3202 SLS1508 DeltaV SISLogic Solver   EMERSON
ACC-68E Delta Tau Digital input and   output cards
1756-OX8I Allen-Bradley ControlLogix   Discrete output module
SDO-0824 HONEYWELL Safe Digital Output   FTA
SDI-1624 HONEYWELL Safe Digital Output   FTA

SYSMAC

CJ1G-CPU44

PROGRAMMABLE

CONTROLLER

OPEN

RUN

ERR/ALM

INH

PRPHL

COMM

MCPWR

BUSY

PERIPHERAL

PORT

RS-232C Port Settings

Peripheral port communications settings when DIP

Switch pin 4 is ON:

Default settings:

Host link mode, 1 start bit, 7 data bits, even parity,

2 stop bits, and a baud rate of 9.600 bps

User-defined settings:

Set the communications mode (host link, NT Link,

or peripheral bus) and other settings such as the

baud rate.

These settings are effective only when pin 5 of the DIP switch on the front of

the CPU Unit is OFF.

The default settings for the RS-232C port are: host link mode, 1 start bit, 7

data bits, even parity, 2 stop bits, and a baud rate of 9.600 bps. Set the RS

232C port settings in the PLC Setup when you need to change these settings.

Specify the frame format when no-protocol mode is selected.

The RS-232C port settings can also be changed with STUP(237). The RS

232C Port Settings Changing Flag (A61902) is turned ON when STUP(237) is

executed and it is turned OFF when the RS-232C port settings have been

changed