Data is accessed in word units. As shown below, the DM area contains both an
area that can be freely used and areas with specific functions.
DM 0000
DM 6144
DM 6450
DM 6541
DM 6569
DM 6600
DM 6655
Fixed DM
(See note 1)
ID error log
ID Error
Statistics Log
Error History
ID Controller
Setup
| 190501-12-00-01 190501 Velomitor CT Velocity Transducer |
| MTL4850MTL HARTmaintenance system |
| PFSA103C ABB Roll Force load cells |
| PFBL141B-75KN ABB Roll Force load cells |
| PFVO143 ABB Matching unit 25A 1638 Hz |
| PFVO142 3BSE023732R1 ABB Matching unit 25A 1638 Hz |
| PFXC141 3BSE029997R1 ABB Junction box PFXC141 |
| ESP10B GE Control board card |
| LM80.A ABB Intermediate range laser level transmitter |
| PPC907BE101 3BHE024577R0101 Inverter module ABB |
| D200137 Metso RT node PC AP31 D200137 personality module |
| D200175 Metso RT node PC AP31 D200175 personality module |
| MC-PHAI01 Honeywell C300 Analog Input Module |
| MC-TAIH04 Honeywell High Level Analog Input/STI FTA for Redundancy (16 Inputs) |
| TC-RPCXX01 Honeywell Redundant Power Supply |
This area has no specific functions and can be used
freely. Both reading and writing are possible from the
program.
This area cannot be written from the program. It is used
for storing information that is not to be changed. Writing
can be executed by means of peripheral devices only.
This area is used to store errors that occur in ID commu
nications. This area cannot be written by the user.
This area records the number of various types of errors
that occur in ID communications. This area cannot be writ
ten by the user.
This area stores the error log. This area cannot be written
by the user.
This area stores information related to ID Controller opera
tion. The settings are made by means of peripheral de
vices.
Note 1. Turning ON pin 1 of the DIP switch on the ID Controller will prevent writing
even by means of peripheral devices.
2. Fixed DM contents, the ID Controller Setup, the user program, and the
instructions table can all be saved to and loaded from a Memory Cassette as
a single unit.
The UM area stores the user’s program. UM area contents can be read and writ
ten only as program data, and not as words. The UM Area can contain up to 3.2K
words of programming
The following table lists the dedicated bits used for the ID Controller.
Word Bit(s) Name Function
SR 232
(Read/Write)
00 AUTOREAD/WRITE Cancel Bit ON: Autoread/write canceled (RUN mode only)
OFF: Autoread/write enabled.
01 Flag Reset Bit ON: SR 233 flags reset except (ID Ready Flag).
OFF: SR 233 flags operative.
02 to 07 Reserved Do not use.
08 Test Bit ON: Test executed (PROGRAM mode only)
OFF: Test stopped.
09 Test Read/Write Bit ON: Write test.
OFF: Read test.
10 ID Error Log Clear Bit ON: Error log cleared. (RUN or PROGRAM mode only)
11 ID Error Statistics Log Clear Bit
g ( y)
Will automatically turn back OFF.
12 to 15 Reserved Do not use.
SR 233
(Read-only)
00 ID Ready Flag Turns ON when ID communications instruction is issued,
turns OFF as soon as instruction is executed, and turns
back ON when communications are completed.
01 ID Completed Flag Turns ON as soon as processing for communications with
Data Carrier via ID communications instruction has been
completed.
02 ID Communications Error Flag Turns ON when an error occurs in communications (ON
when any flag between SR 23308 and SR 23313 is ON).
Turns OFF when error is cleared and ID communications
instruction is executed.
03 to 05 Reserved Do not use.
06 DC Battery Warning Flag Turns ON when the voltage of the battery built into the Data
Carrier is low, indicating the battery has passed its service
life.
07 ID Check Warning Flag Turns ON when an error is detected for the IDMD (66)
(ID CHECK) instruction.
08 DC Missing Error Flag Turn ON when corresponding error is detected,
09 Write Protected Error Flag
p g ,
Turn OFF when SR 23201 (Flag Reset Bit) turns ON.
10 DC Communications Error Flag
Turn OFF when SR 23201 (Flag Reset Bit) turns ON.
Turn OFF when ID communications instruction is executed.
11 Address Error Flag
Turn OFF when ID communications instruction is executed.
12 Verification Error Flag
13 No Head Error Flag
14. 15 Reserved Do not use.
SR 234
(Read-only)
00 to 07 Error Code 70 to 7D ID communications in progress: FFFF
Normalend: Instructioncode+“00” (Readonly)
08 to 11 Instruction Code 1 to 6 Normal end: Instruction code + “00”
Error end: Instruction code + error code
12 to 15 Reserved Do not use.
SR 235 to
SR 239
00 to 15 Reserved Do not use