OMRON CQM1H-ADB21  PLC

OMRON CQM1H-ADB21  PLC

Data is accessed in word units. As shown below, the DM area contains both an

area that can be freely used and areas with specific functions.

DM 0000

DM 6144

DM 6450

DM 6541

DM 6569

DM 6600

DM 6655

Fixed DM

(See note 1)

ID error log

ID Error​

Statistics Log

Error History

ID Controller

Setup

190501-12-00-01 190501 Velomitor CT Velocity Transducer
MTL4850MTL HARTmaintenance system
PFSA103C ABB Roll Force load cells
PFBL141B-75KN ABB Roll Force load cells
PFVO143 ABB Matching unit 25A 1638 Hz
PFVO142 3BSE023732R1 ABB Matching unit 25A 1638 Hz
PFXC141 3BSE029997R1 ABB Junction box PFXC141
ESP10B GE Control board card
LM80.A ABB Intermediate range laser level transmitter
PPC907BE101 3BHE024577R0101 Inverter module ABB
D200137 Metso RT node PC AP31 D200137 personality module
D200175 Metso RT node PC AP31 D200175 personality module
MC-PHAI01 Honeywell C300 Analog Input Module
MC-TAIH04 Honeywell High Level Analog Input/STI FTA for Redundancy (16 Inputs)
TC-RPCXX01 Honeywell Redundant Power Supply

This area has no specific functions and can be used

freely. Both reading and writing are possible from the

program.

This area cannot be written from the program. It is used

for storing information that is not to be changed. Writing

can be executed by means of peripheral devices only.

This area is used to store errors that occur in ID commu

nications. This area cannot be written by the user.

This area records the number of various types of errors

that occur in ID communications. This area cannot be writ

ten by the user.

This area stores the error log. This area cannot be written

by the user.

This area stores information related to ID Controller opera

tion. The settings are made by means of peripheral de

vices.

Note 1. Turning ON pin 1 of the DIP switch on the ID Controller will prevent writing

even by means of peripheral devices.

2. Fixed DM contents, the ID Controller Setup, the user program, and the

instructions table can all be saved to and loaded from a Memory Cassette as

a single unit.

The UM area stores the user’s program. UM area contents can be read and writ

ten only as program data, and not as words. The UM Area can contain up to 3.2K

words of programming

The following table lists the dedicated bits used for the ID Controller.

Word Bit(s) Name Function

SR 232

(Read/Write)

00 AUTOREAD/WRITE Cancel Bit ON: Autoread/write canceled (RUN mode only)

OFF: Autoread/write enabled.

01 Flag Reset Bit ON: SR 233 flags reset except (ID Ready Flag).

OFF: SR 233 flags operative.

02 to 07 Reserved Do not use.

08 Test Bit ON: Test executed (PROGRAM mode only)

OFF: Test stopped.

09 Test Read/Write Bit ON: Write test.

OFF: Read test.

10 ID Error Log Clear Bit ON: Error log cleared. (RUN or PROGRAM mode only)

11 ID Error Statistics Log Clear Bit

g ( y)

Will automatically turn back OFF.

12 to 15 Reserved Do not use.

SR 233

(Read-only)

00 ID Ready Flag Turns ON when ID communications instruction is issued,

turns OFF as soon as instruction is executed, and turns

back ON when communications are completed.

01 ID Completed Flag Turns ON as soon as processing for communications with

Data Carrier via ID communications instruction has been

completed.

02 ID Communications Error Flag Turns ON when an error occurs in communications (ON

when any flag between SR 23308 and SR 23313 is ON).

Turns OFF when error is cleared and ID communications

instruction is executed.

03 to 05 Reserved Do not use.

06 DC Battery Warning Flag Turns ON when the voltage of the battery built into the Data

Carrier is low, indicating the battery has passed its service

life.

07 ID Check Warning Flag Turns ON when an error is detected for the IDMD (66)

(ID CHECK) instruction.

08 DC Missing Error Flag Turn ON when corresponding error is detected,

09 Write Protected Error Flag

p g ,

Turn OFF when SR 23201 (Flag Reset Bit) turns ON.

10 DC Communications Error Flag

Turn OFF when SR 23201 (Flag Reset Bit) turns ON.

Turn OFF when ID communications instruction is executed.

11 Address Error Flag

Turn OFF when ID communications instruction is executed.

12 Verification Error Flag

13 No Head Error Flag

14. 15 Reserved Do not use.

SR 234

(Read-only)

00 to 07 Error Code 70 to 7D ID communications in progress: FFFF

Normalend: Instructioncode+“00” (Readonly)

08 to 11 Instruction Code 1 to 6 Normal end: Instruction code + “00”

Error end: Instruction code + error code

12 to 15 Reserved Do not use.

SR 235 to

SR 239

00 to 15 Reserved Do not use