2.3.1 Multi-bridge and Power Bridge Redundancy

The EX2100e control multi-bridge option is available for large static exciters. This option

uses redundant controls (M1. M2. and C) with up to four full-wave SCR bridges that

share common ac input and dc output circuits. The multi-bridge configuration is

applicable to 8.000 A dc, 50/60 Hz, and may be configured as follows:

N+0. N =2. 3

N+1. N =2. 3

N+2. N =1. 2

A power bridge online

maintenance feature that uses

a 5-pole disconnect switch is

available.

All power bridges receive gating commands from the active control (M1 or M2), and

support the full field voltage and current needs of the generator field. The operator has

full control to select which of the redundant controls are active or inactive. Bi-directional

bumpless transfer between active and inactive controls is standard. In the N+1 and N+2

configurations, sophisticated monitoring and protection circuits detect a failure or

misoperation of any single power bridge, and exciter operation continues while the faulty

bridge is automatically shut down.

Product Description

GEA-S1302A 9

For public disclosure

2.3.2 WarmBackupandPowerBridgeRedundancy

The EX2100e control WBU option is available for small to medium sized static exciters,

which require power bridge redundancy, and the total power needs of the generator field

can be supported within one PCM. This option uses redundant controls (M1. M2. and C)

with two full-wave SCR bridges that share common ac input and dc output circuits.

The WBUconfiguration is a

cost-effective way to obtain

N+1 bridge redundancy

when N =1.

The active power bridge receives the gating commands from the active control (M1 or

M2) and supports the full field voltage and current needs of the generator field while the

backup power bridge’s gating circuit is inhibited. The operator has full control to select

which of the redundant power bridges is active or inactive. Bi-directional bumpless

transfer between active and inactive bridges is standard. Sophisticated monitoring and

protection circuits detect a failure or misoperation of the active power bridge, delays

transfer (if needed to clear and SCR leg fuses), and activates the backup power bridge

without operator intervention

PP846A 3BSE042238R2   touchscreen operator panel
IS200TREAH2A SPEEDTRONICTurbine Control
IS220PAICH1A Described as an Analog I/O   Pack
489-P5-LO-A20-E 469 Motor Protection   Relay
MDD112D-N-030-N2L-130GA0 MDD series of   digital AC servo motor
A06B-6252-H075 Power Supply Module
IS420UCSCH2A-C Mark VIe Embedded   Controller with a PMAC processor
IS200TTURH1CFD termination board
CPCI-5565PIORC-110000 Ultrahigh Speed   Fiber-Optic Reflective Memory
IS200EPCTG1A Input/Output Terminal Board
VMIVME-5565-110000 VME-5565 Reflective   Memory
IS220PSVOH1A PSVO Servo Control Module
IS220PPROH1A Turbine specific I/O module
9907-1200 second generation   current-to-pressure converters (CPC-II)
IS220PVIBH1A Vibration Terminal Board   (TVBA)
FCP280 RH924YF Field Control Processor   280
IC698CPE030 Rx7i PACsystem CPU   IC698CPE020
IS220PPDAH1A Power Distribution Feedback   board
1756-L72EROMS Armor ControlLogix   Controller
IS200ESYSH3AAA Simplex Control I/O   terminal board