ALSTOM

ALSTOM PIB-100G Interface Board Module

Navigation Key

The 4-way Navigation key is used to navigate menus and parameters, and to edit parameter values.

Operation of the Navigation key is shown in Figure 2-1.

Navigating Menus and Parameters

Figure 2-2 shows how to navigate the menus and parameters to find any parameter.  Menu 1 and its

parameters are illustrated as an example.  Other menus are treated in exactly the same way.  To access

menus other than Menu 1. edit parameter P1.31 as shown in Section 3.2.2.

The start-up screen displayed when the drive is first switched on is shown as shaded, this shows the default

value for P1.00.

Editing Parameters

Two types of parameter may be edited:

NUMERICAL parameters – to change the value.

LIST parameters – to choose from a list.

The factory default settings can be regained if desired – see 3.2.4.

NUMERICAL Parameter

As an example of editing “numerical” parameters, Figure 2-3 shows how to edit the value of the Motor Base

Frequency parameter P2.00.

LIST Parameter

This type of parameter contains a list of sources, items etc.  Figure 2-4 shows how to select from a “list”

parameter, using the Speed Reference 1 Source parameter P5.01 as an example.

Using The Keypad HELP (?) Key

The     ?    key can provide diagnostic help or parameter help, this help function is context sensitive.  Section

9 describes the use of the    ?    key during diagnostics, and Figure 2-3 and Figure 2-4 (Numerical and List

parameters) show examples of how to get Parameter help.

SHORTCUT Method of Entering a Parameter Number

If the parameter number is known, it can be entered directly using a shortcut method.  Press the relevant

alphanumeric keys to enter the desired Parameter Number, including the letter P and the decimal point.  For

example enter P5.01 to select the Speed Ref. 1 Source parameter previously referred to.

Removal of the Drive Data Manager™ (Keypad)

NOTE: To allow the drive to make the necessary safety checks, this removal procedure should always be

followed.  A trip may result if this procedure is not followed.

The drive checks if Keypad removal is allowed as the Keypad may have Start/Stop control, or the Keypad

Speed Reference may be active.

To remove the Keypad, continue as shown in Table 2-1.

Ensure the keypad is neither in control of

the Start/Stop nor the keypad Speed

Reference is active

AT DEFAULT:

Simply close DIGIN4. this will select

Remote.

ELSE:

Gain the necessary authorisation

before continuing.

a)  Make P34.16 = 1. to set CF116 ON, this

removes the Start/Stop control from the keypad.

b)  If a machine bridge, the keypad must

not be either the active reference source or the

backup reference source. The reference sources

are held in P5.01 to P5.05 and are made active

by CF4 to CF7 (P5.07 to P5.10) respectively.

2 Access the keypad removal screen

Press the “esc” key repeatedly.

3 Select “REMOVAL CHECK” Press the “1” key on the keypad

The converter checks to see if the keypad is

allowed to be removed. As well as the above

control and reference checks, P35.01 (Allow

keypad Removal) is also checked.

4 Remove keypad if the screen allows:

A message may be flashed disallowing removal

because the keypad is either still in control, still

has active/backup reference

(see step 1 above) or if it is simply disallowed (see

step 3 above).

GE IS220PAOCH1A
GE IS220PDIAH1A
GE IS220PDIAH1A 336A4940CSP1
GE IS220PDIAH1B
GE IS220PDIAH1BE 336A5026ADP4
GE IS220PDIIH1B 336A5026ADP1
GE IS220PDIOH1A
GE IS220PDOAH1A
GE IS220PDOAH1A 336A4940CSP2
GE IS220PDOAH1B
GE IS220PPDAH1B
GE IS220PPRFH1A