FOXBORO

FOXBORO RH924YF – Foxboro Process Module

Static Pressure Effect on Differential Pressure

The zero and span shift for a 7 MPa, 1000 psi,

change in static pressure is:

ZERO SHIFT (a)

Span Code

Zero Shift-Static Pressure Effect

±0.30% URL (b)

B and C

±0.10% URL

±0.50% URL  (b)

±0.50% URL

a. Can be calibrated out by zeroing at nominal line

pressure.

b. Per 3.5 MPa (500 psi) for Span Codes A and D.

SPAN SHIFT

±0.25% Reading (±0.030% for Span Code A)

Vibration Effect

Total effect is ±0.2% of URL per “g” for vibrations in

the frequency range of 5 to 500 Hz; with double

amplitudes of 6.3 mm (0.25 in) in the range of 5 to 15

Hz, or accelerations of 3 “g” in the range of 15 to 500

Hz, whichever is smaller, for transmitters with

aluminum housings; and with double amplitudes of

6.3 mm (0.25 in) in the range of 5 to 9 Hz, or

accelerations of 1 “g” in the range of 9 to 500 Hz,

whichever is smaller, for transmitters with 316 ss

housings.

PELCO PA30-0065-00-A1
PENTEK FILTER 3F11 800000919
PENTEK PC.8297023L 320-71400
PEPPERL+FUCHS 2108HAT
PEPPERL+FUCHS HID2082
PEPPERL+FUCHS RSD-CI-EX8
PEPPERL+FUCHS RSD-TI-EX8
PERITEK AC7-00712-1113
PHILIPS 958481223220
PHILIPS 958481223223
PHILIPS 958481320100 LCB
PHILIPS 958481320201 PROC PLUS
PHILIPS 958481320201 PROC+
PHILIPS 958481320400 PIF
PHILIPS 958481321200 PD216

Fill Fluid

Silicone Oil or Inert FC43

Process Wetted Materials

PROCESS CONNECTION

316L ss, cs, Monel, or Nickel alloy, or PVDF

(Kynar)

SENSOR DIAPHRAGM

316L ss, Co-Ni-Cr, Monel, Tantalum, Nickel

alloy, or Gold-Plated 316L ss, as specified

GASKET

Glass-filled PTFE

Pressure Seal Diaphragm Material

Varies with pressure seal selected. See

PSS 2A-1Z11 A.

Dimensions

Refer to “DIMENSIONS – NOMINAL” on page 36

and to Dimensional Print DP 020-447.

Approximate Mass (with Process Connectors)

4.2 kg (9.2 lb) – with Traditional Structure

Add 0.1 kg (0.2 lb) – with Low Profile Structure LP1

Add 0.8 kg (1.8 lb) – with Low Profile Structure LP2

Add 1.1 kg (2.4 lb) – with 316 ss Housing

Transmitter prepared for Foxboro Model Coded Remote Mount Seals (b)

Transmitter prepared for Remote Seals on Both HI and LO Sides, Silicone Fill in Sensor

Transmitter prepared for Remote Seals on Both HI and LO Sides, Inert Fill in Sensor

S1 (c)

S2 (c)

Transmitter prepared for Remote Seal HI Side, 1/2 NPT Connector LO Side, Silicone Fill in Sensor

Transmitter prepared for Remote Seal HI Side, 1/2 NPT Connector LO Side, Inert Fill in Sensor

S3 (c)

S4 (c)

Transmitter prepared for Remote Seal LO Side, 1/2 NPT Connector HI Side, Silicone Fill in Sensor

Transmitter prepared for Remote Seal LO Side, 1/2 NPT Connector HI Side, Inert Fill in Sensor

S5 (c)

S6 (c)

5. Transmitter Prepared for Foxboro Model Coded Direct Connect Seals (b)

PSFLT, PSSCT, or PSSST Direct Connect Seal on HI Side; 1/2 NPT Process Connector LO Side; Silicone Fill

PSFLT, PSSCT, or PSSST Direct Connect Seal on HI Side; 1/2 NPT Process Connector LO Side; Inert Fill

PSFLT, PSSCT, or PSSST Direct Connect Seal on HI Side; Remote Seal with Capillary LO Side; Silicone Fill

PSFLT, PSSCT, or PSSST Direct Connect Seal on HI Side; Remote Seal with Capillary LO Side; Inert Fill

6. Transmitter Prepared for non-Foxboro Seals

Remote Seals on High and Low Sides; Silicone Fill in Sensor

Remote Seals on High and Low Sides; Inert Fill in Sensor

Remote Seal on High Side and 1/2 NPT Connector on Low Side, Silicone Fill in Sensor

Remote Seal on High Side and 1/2 NPT Connector on Low Side, Inert Fill in Sensor

Remote Seal on Low Side and 1/2 NPT Connector on High Side, Silicone Fill in Sensor

Remote Seal on Low Side and 1/2 NPT Connector on High Side, Inert Fill in Sensor

Span Limits

kPa inH2O mbar

0.12 and 7.5 0.5 and 30 1.2 and 75

0.87 and 50 3.5 and 200 8.7 and 500

7 and 210 28 and 840 70 and 2100

MPa psi bar

0.07 and 2.1 10 and 300 0.7 and 21

0.7 and 21 100 and 3000 7 and 210

Process Connector Type (Material Same as Process Cover Material) (f)

See below:

For d/p: No connectors; both covers tapped for 1/4 NPT (316 ss only, no side vents)

Flange Mount Hi Side: 1/2 NPT, 316 ss Process Connector on Lo Side (F1 and F2 only)

Flange Mount Hi Side: No connectors; both sides prepared for seals (F3 and F4 only)

Two Remote Seals: No connectors; both covers tapped for capillary connection (S1. S2. SA, SB only)

One Remote Seal: 1/2 NPT, 316 ss Process Connector on Side Opposite Seal (S3 to S6. SC to SF only)

1/4 NPT, Not with Structure Codes 46 to 49. 78. 79. or pressure seals

1/2 NPT, Not with Structure Codes 78 or 79. or pressure seals

Rc 1/4. Not with Structure Codes 46 to 49. 78. 79. or pressure seals

Rc 1/2. Not with Structure Codes 78 or 79. or pressure seals

1/2 Schedule 80 Welding Neck, Not with Structure Codes 46 to 49. 78. 79. or pressure seals

None; PVDF Insert tapped for 1/2 NPT/Process Inlet on Side of 316 ss Process Covers (only with 78/79 above)

Conduit Connection and Housing Material

1/2 NPT Conduit Connection, Aluminum Housing

PG 13.5 Conduit Connection, Aluminum Housing (With Electrical Safety Code D only)

1/2 NPT Conduit Connection, 316 ss Housing

PG 13.5 Conduit Connection, 316 ss Housing (With Electrical Safety Code D only)

M20 Conduit Connection, Both Sides, Aluminum Housing (With Electrical Safety Code D only)

M20 Conduit Connection, Both Sides, 316 ss Housing (With Electrical Safety Code D only)

发表回复