Triconex Model 2451 Solid-State Relay Output Baseplate
Tricon Key capabilities
• TÜV-certified for SIL3 applications to international standard IEC61508
• High-availability architecture for continuous operation
• Fault-tolerant architecture for continuous operation even under fault conditions
• Choice of form factors
• Online module replacement ensures continuous operation and plant availability
• Online upgrade without process interruption
• Direct Integration with Foxboro®Evo process automation system
• Easily integrated with all major distributed control systems
• ISA Secure EDSA Level 1 right out of the box
• Works in both centralized and distributed applications
• HART protocol pass through to Asset Management Systems
• Fast program cycle time from 10 mS
• 1 mS SOE Digital Input
• Choice of termination options — Direct and ETP
• Expertise available from our TÜV-certified Functional Safety Experts and Engineers
• Continually current technology
• Comprehensive family of I/O modules
| INDRAMAT | MAC112C-0-ED-2-C/180-B-0/S003 |
| INDRAMAT | MAC112C-0-HD-2-C/180-A-2/S029 |
| INDRAMAT | MAC112C-0-HD-4-C/180-A-0/WI516LV/SO11 |
| INDRAMAT | MAC112D-0-ED-2-C/180-A-0/S011 |
| INDRAMAT | SKM-3S-94V0 |
| INFICON | 0190-51546REV03 |
| INFICON | MPG400 PN351-011 |
| INFICON | PSG400 |
| INFINEON | BSM75GD120DLC |
| INFINEON | V23818-M305-B57 |
| INGERSOLL RAND | AAP3798102-00140 |
| INSPIRED ENERGY | NL2024HU22 |
TRICONEX TRIPLE MODULAR REDUNDANCY
Tricon operation is based on the principle of safety and high plant availability, which identifies and
compensates for failed control system elements and allows on line replacement while continuing
its assigned task without interrupting the controlled process. Fault Tolerance is achieved through TMR technology.
TMR employs three isolated, parallel control systems and extensive diagnostics integrated into one
system. The Tricon system uses two-out-of-three (2oo3) voting to provide high integrity, error-free,
uninterrupted process operation with no single point of failure. Setting up applications is simplified
with the Tricon, because the TMR system operates as a single control system from the user’s point of
view. The extensive diagnostics are inherent and transparent to the programmer.
Use of the Tricon continues to expand into new industries and applications as customers require
increased system safety and/or high availability. Today, Invensys has delivered and installed Triconex
safety system solutions in over 70 countries, providing increased safety and high process uptime.
KEY CAPABILITIES
• TÜV Certified up to SIL3 applications in accordance with International standard IEC61508
• Easily integrated with all major Distributed Control Systems
• On-line module replacement ensures plant availability by hot-swapping of modules
• Works with both centralized and distributed applications
• Comprehensive family of I/O modules
• HART protocol pass through to Asset Management Systems
• Fast program cycle time for TMC applications
• Expertise available from our TÜV certified Functional Safety Experts and Engineers
• Certified for use in non-incendive applications