Triconex 3603B/E/T 120Vdc Digital Output
Products Description
Manufacturer : Triconex
Product No. : 3603B/E/T
Product type : Digital Output Module
Type : TMR
Output current range : 4-20 mA Input (+6% overrange)
Number of output points : 8
Isolated points : No, commoned return, DC coupled
Resolution : 12 bits
Output Accuracy : <0.25% (in range of 4-20 mA) of FSR (0-21.2 mA), from 32° to 140° F (0° to 60° C)
Over-range protection : +42.5 VDC, continuous
Switch time on leg failure : < 10 ms, typical
Color code : Pea Green
Weight : 4 kg
Dimension : 9 kg
Shipping weight : 5.6 kg
The Triconex Tricon Safety Instrumented System is designed to meet the needs of safety and critical
control applications in oil and gas, power, refining, chemicals, pharmaceutical and biotech industries.
It is based on industry leading TMR technology, is easy to operate and maintain and provides the lowest total cost of ownership.
Models 3502E, 3503E, and 3505E can self-test to detect stuck-On conditions where the circuitry
cannot tell whether a point has gone to the Off state.
Since most safety systems are set up with a deenergize-to-trip capability, the ability to detect Off points is an important feature.
To test for stuck-On inputs, a switch within the input circuitry is closed to allow a zero input (Off) to be read by the optical isolation circuitry.
The last data reading is frozen in the I/O communication processor while the test is running.
EcoStruxure™ Triconex® – Tricon CX
EcoStruxure™ Triconex Safety System – superior protection for people, production and profits
We understand that you need more from your safety instrumented systems than just keeping your operations safe
you need to keep operations running continuously, avoiding any unexpected downtime or interruption that impacts profitability.
EcoStruxure Triconex – Tricon CX is the most powerful safety system from Triconex.
Leveraging the pedigree of the field-proven Tricon, Trident and Tri-GP systems,
Tricon CX is the best possible choice when safety and profitability are critical success factors.
Applications
• Emergency Shutdown (ESD)
• Burner Management Systems (BMS)
• Fire and Gas Systems (F&G)
• High Integrity Pressure Protection systems (HIPPS)
• Turbo Machinery Controls (TMC)
• Control of critical applications
Operating principals
• Fail Safe — De-energize to trip
• Energize to trip
• Safe, available, secure
Communications
• SIL3 Peer to Peer (254 Nodes)
• OPC DA and A&E (embedded server)
• Modbus TCP/IP Master and Slave
• Modbus Serial Master and Slave
• TSAA
• Copper and Fiber Optic
• ISA Secure EDSA Level 1
9671-810 (24 VDC, commoned interposing relay, 16 pts.)
Termination panel 9671–810 is compatible with 24 VDC digital output modules and has:
• 16 relay points (C and NO)
• 2 terminals (PW1 + and –) for primary power and return
• 2 terminals (PW2 + and –) for redundant power and return
• An indiv
idualf
use w
ith b
lown-fuse indicator for relay coil and loopback circuit
When using 32-point modules, you must use two term panels for each digital output module.
Each term panel comes with two sets of labels: 1-16 and 17-32. For information on how to apply
the labels, see Appendix F, Panel Labels.
Each terminal accepts either #6 ring-lug terminals or 24-to-12-gauge (0.3mm2 to 2.1mm2) wires