Triconex 3722X 0-5Vdc Analog Input
Indicators are lights on the front panel of each module that identify the state of each module.
Each module includes indicators that identify the general state of the module and other indicators related to the function of the module.
The types of indicators include:
• Status indicators which identify the processing state of the module.
Each module includes a Pass, Fault, and Active indicator.
• A lock indicator which identifies whether the module is unlocked.
• Mode indicators which identify the current operating state of the controller.
(Only on MP Modules.)
• Field power and power load indicators which identify whether a power
problem has occurred. (Only on some I⁄O modules.)
• Communication indicators which identify the type of communication occurring.
(Only on MP and CM Modules.)
• Points indicators which identify whether the point is energized.
• Alarm indicators which identify alarm conditions for the controller.
(Only on MP Modules.)
| TRICONEX | 3626X |
| GE | MIB30HICE00000 |
| ABB | NDCU-11 |
| GE | IS220PRTDH1A |
| ABB | 3BDH000002R1 PM802F |
| HARMONIC | HA-800A-3C-200 |
| A-B | T9110 |
| A-B | T9451 |
| ROLLS ROYCE | 984664H |
| GE | SR469-P5-HI-A20 |
| EATON | MA30/D/2/SI |
| ABB | 2TLJ020070R0500 |
| GE | KYPDACGP1 |
| GE | DS3800HIOB |
| GE | DS3800NGRD1D1C |
| ABB | AO2040 |
| WOODWARD | 5463-787 |
| WOODWARD | 5501-429 |
| MOOG | D651-129B |
| ABB | HMI REF542 PLUS |
| ABB | REF615 HBFJAEAGAAC1BAA11G |
EcoStruxure™ Triconex® – Tricon CX
EcoStruxure™ Triconex Safety System – superior protection for people, production and profits
We understand that you need more from your safety instrumented systems than just keeping your operations safe
you need to keep operations running continuously, avoiding any unexpected downtime or interruption that impacts profitability.
EcoStruxure Triconex – Tricon CX is the most powerful safety system from Triconex.
Leveraging the pedigree of the field-proven Tricon, Trident and Tri-GP systems,
Tricon CX is the best possible choice when safety and profitability are critical success factors.
The Tricon system is a must for clients who need to maximize the safety and
performance of their assets. If you are challenged with reducing investment and
lifecycle costs, meeting new safety standards, combating tough competitive
pressure in your markets as well as the welfare of your employees and the
environment, then the Tricon system is designed for you.
A powerful, scalable design with assurance
of continuous operation, the Tricon system complies with international safety
standards such as IEC61508 and fulfils the requirements for applications such as
Emergency Shutdown (ESD), Fire and Gas Protection (F&G), Burner Management
(BMS), High Integrity Pressure Protection (HIPPS) and Turbomachinery Control
(TMC). The redundant high availability architecture provides a flexible, robust,
reliable and powerful solution that is ideal for clients looking to achieve
environmental and safety excellence.
KEY CAPABILITIES
• TÜV Certified up to SIL3 applications in accordance with International standard IEC61508
• Easily integrated with all major Distributed Control Systems
• On-line module replacement ensures plant availability by hot-swapping of modules
• Works with both centralized and distributed applications
• Comprehensive family of I/O modules
• HART protocol pass through to Asset Management Systems
• Fast program cycle time for TMC applications
• Expertise available from our TÜV certified Functional Safety Experts and Engineers
• Certified for use in non-incendive applications