TRICONEX 3511 – Main Processor Module, Modular, High-Performance
This table identifies termination products you can use with 32-point analog input modules.
Note You need two termination panels (or cables) for each 32-point AI module. Also, you can
mix any combination of two termination products listed in a particular module’s
column. For example, with 0–5 VDC modules you may choose two 9763-810 panels, or
a 9753-110 basic panel and a 9764-310 RTD/TC/AI panel, and so on.
Table 13 Termination Products for 32-Point Analog Input Modules
Termination Option 0–5 VDC (3700A) 0–10 VDC (3701) 0 to 5 VDC or –5 to
+5 VDC (3721)
Standard termination panel,
voltage input
9763-810 9763-810 9763-810
Standard termination panel,
current input
9761-210 9761-410 9761-210
Standard termination panel,
current input,
user configurable
9771-210 n/a 9771-210 (0–5 V)
9761-410 (0–10 V)
Basic termination panel, voltage
input
9753-110 9753-110 9753-110
Nonincendive termination panel,
current input
9791-610 n/a 9791-610
Nonincendive termination panel,
voltage input
9787-110 n/a 9787-110
RG 1.180 Term Panel 9790-610
(current input)
9792-610 (4-20
mA, 0-5 V, 48
VDC field)
9783-110
(voltage input)
9764-310.
RTD/TC/AI
input
n/a 9790-610
(4–20 mA, 0–5 V)
9792-610 (4-20 mA,
0-5 V, 48 VDC field)
9795-610
(4–20 mA, 0–10 V)
9783-110
(voltage input)
9764-310.
| TRICONEC | 3603T |
| TRICON | 4355X |
| Triconex | 4000189-530 |
| ABB | PFVL142(16MM) |
| ABB | AT868-2-1-1 |
| ABB | FVL141V-16MN |
| Meggitt | IOC-CARD FOR MPC4 200-560-0001HH |
| GE | DS200TCDAH1B |
| GE | DS200TCPSG1A |
| Yokogawa | S2CP471-01 S2CP471-01 |
| Prosoft | MVI56-PDPS |
| GE | DS200TCDAH1B |
| Uniop | ETOP515U3P1 |
| GE | 350-L-P5-G5H-E-E-C-P |
| GE | IS420UCSBH3A |
| GE | PKSK 126 3B5E002097R1 |
| GE | XDP-221-1-S |
| ALSTOM | 029.381208 |
| MOOG | G122-829A |
| GE | HYDRAN 201 Ti |
RTD/TC/AI input
RTD/TC/AI panel 9764-310 n/a n/a
Fanned-out cable Contact Triconex for availability of analog fanned-out cables.
Table 14 Termination Products for 64-Point Analog Input Modules
Termination Option 0–5 VDC or 0–10 VDC
(3704E) 0–5 VDC (3720)
Standard termination panel, 3-wire
Xmtr
9765-210 9765-210
Standard termination panel, current
input
9760-210 (0–5 V)
9760-410 (0–10 V)
9760-210 (0–5 V)
9760-410 (0–10 V)
Basic termination panel, current input 9750-210 (0–5 V) 9750-210
Table 14
Termination Products for 64-Point Analog Input Modules (continued)
Termination Option
0–5 VDC or 0–10 VDC
(3704E)
0–5 VDC (3720)
Basic termination panel, voltage input
9750-810 (0–5 V/0–10 V)
9750-810
Nonincendive termination panel,
current input
9789-610
9789-610
Fanned-out cable
Contact Triconex for availability of analog fanned-out
cables.