SAUTER Valve actuator ASM 105S/115S series ASM105SF152
SAUTER Valve actuator ASM 105S/115S series ASM105SF152
Universal Technology (SUT)
How energy efficiency is improved
Torque-dependent cut-off facility for efficient usage of energy
Features
• For controllers with switching (2- and 3-point) or continuous output (0…10 V)
• Self-centring spindle adapter
• Gear unit can be disengaged to position the damper and for manual adjustment
• Stepping motor with electronic activation and cut-out
•Maintenance-free
• Intelligent adaptation of rotation angle, incl. feedback adjustment
• Free configuration using the CASE Drive PC tool
• Suitable for all fitting positions
Technical data
Power supply
Power supply 24 V~ ±20%, 51…60 Hz
Power supply 24 V= ±20%
Parameters
Angle of rotation Max. 95°
Admissible damper shaft Ø 8…16 mm, □ 6.5…12.5 mm
Admissible damper shaft (hardness) Max. 300 HV
Operating noise < 30 dB (A)
Response time 200 ms
Positioner Control signal y 0…10 V, Ri > 100 kΩ
Positional feedback signal y0 0…10 V; load > 10 kΩ
Starting point U0 0 or 10 V
Control span ΔU 10 V
Switching range Xsh 200 mV
Ambient conditions
Admissible ambient temperature–20…55 °C
Admissible ambient humidity < 95% rh, no condensation
Construction
Weight 0.7 kg
Housing Lower section black, upper section
yellow
Housing material Fire-retardant plastic
Power cable 1.2 m long, 5 × 0.5 mm²
Standards and directives
Type of protection IP54 (EN 60529)
Protection class III (IEC 60730)
CE conformity EMC Directive 2014/30/EU EN 61000-6-1
EN 61000-6-3
EN 61000-6-4
Directive 2006/95/EC EN 1050
Overview of types
Type Rotational torque and holding
torque (Nm)
Running time for 90° Power consumption
ASM105SF132 5 35/60/120 s 5.0 W, 9.0 VA
ASM115SF132 10 60/120 s 4.8 W, 8.7 VA
Description of operation
Depending on the type of connection (see connection diagram), the actuator can be used as a contin
uous 0…10 V, 2-point (OPEN/CLOSE) or 3-point actuator (OPEN/STOP/CLOSE) with an intermediate
position. The running time of the actuator can be set with switches S1 and S2 according to require
ments.
The manual adjustment is performed by releasing the gear unit using the adjuster beside the connec
tion cable and simultaneously adjusting the spindle adaptor.
Intended use
This product is only suitable for the purpose intended by the manufacturer, as described in the “De
scription of operation” section.
All related product regulations must also be adhered to. Changing or converting the product is not ad
missible.
Additional technical data
The upper section of the housing with the cover, indicator knob and cover knob contains the stepping
motor and the SUT electronics.
The lower section of the housing contains the maintenance-free gear unit, the gear-release lever and
the spindle adaptor.
Auxiliary change-over contacts
Switch rating max. 230 V AC, current min. 20 mA at 20 V
Switch rating max. 4…30 V DC, current min. 1…100 mA
Power consumption
Type
Running time [s]
Status
Active power [W]
ASM 105S F132
Connection as 2-point control unit
This OPEN/CLOSE activation can be performed via 2 cables. The actuator is connected to the volt
age via the blue and brown cables. The damper actuator is moved to the end position by connecting
the voltage to the black cable (clockwise direction to 100% angle of rotation). After the voltage is
switched off, the actuator moves to the opposite end position. The unused red and grey wires must
not be connected or come into contact with other cables. We recommend that you insulate these.
| Metso, | ND9106FN |
| GE | IS230JPDGH1B |
| Meggit | 200-510-071-113 |
| ABB | 306A4576P001 |
| GE | 246B9953BMG01 |
| Mentor | MP420A4R |
| KEBA | SC102 |
| RELIANCE | 45C922 |
| RELIANCE | 57C554 |
| ABB | HESG324430R11/B |
| FOXBORO | fbm232 |
| A-B | IMASO01 |
| A-B | IMDSO04 |
| Yokogawa | YNT511D-V42/KT |
| ABB | NTAI05 |
| GE | SGHA36AT0400 |
| AB | TLY-A2540P-HK64AA |
| Foxboro | FCM10Ef P0916CP |
| Mitsubishi | FXDOM01(OMN1) |