AEROTECH

AEROTECH TM Series Transformers

TM Series Transformers
The TM3 transformer module provides and distributes isolated AC or DC bus supply voltages for up to four Aerotech controllers and has a maximum transformer output power capability of 300 watts.

The TM5 transformer module is used to provide and distribute isolated AC bus supply voltages for up to four Aerotech controllers and has a total output power capability of 500 watts.
Design Features
Provides AC or DC bus supply voltages for up to four Aerotech controllers
300 watts max power output (TM3); 500 watts max power output (TM5)
Auxiliary supply outputs for powering up to four additional products
TM3 Transformer Module
The TM3 transformer module is configured at the factory to provide 28 VAC, 56 VAC, 115 VAC, 40 VDC, 80 VDC or 160 VDC with a maximum transformer output power capability of 300 watts.

TM

Additionally, the TM3 provides auxiliary supply outputs for powering the auxiliary power inputs of up to four Aerotech products. The TM3 also includes a 24 VDC power supply that provides the user with 24 VDC output. Other features of the TM3 include a soft-start circuit to limit inrush current and a voltage selector that can be configured for AC input voltages of 100 VAC, 115 VAC, 200 VAC, or 230 VAC.

TM5 Transformer Module
The TM5 transformer module is configured at the factory to provide 28 VAC, 56 VAC, 115 VAC or a combination of these voltages with a total output power capability of 500 watts. Additionally, the TM5 distributes the applied AC line voltage to each of the auxiliary supply outputs for powering the auxiliary power inputs of other Aerotech products. The TM5 may also be purchased with the 24 VDC power supply option that provides the user with 24 VDC output.

TM Series Specifications

Model TM3 TM5
Type Isolation Isolation
AC Input Configurations 100 VAC, 115 VAC, 200 VAC, 230 VAC 100 VAC, 115 VAC, 200 VAC, 230 VAC
Peak AC Input Inrush Current 32 Apk 200 Apk
Operating Frequency 50/60 Hz 50/60 Hz
Maximum Continuous Transformer Output Power 300 watts max @ 20°C 500 watts max @ 20°C
Peak Transformer Output Power 400 watts max @ 20°C 800 watts max @ 20°C
Short Circuit/Over Current Protection AC input 10 A breaker/switch (supplementary protection only); 100 VAC/115 VAC configurations contain 4 A slow-blow fuse connected to transformer primary winding; 200 VAC/230 VAC configurations contain 3 A slow-blow fuse connected to transformer primary winding AC input 10 A breaker/switch (supplementary protection only); 100 VAC/115 VAC configurations contain 8 A slow-blow fuse connected to transformer primary winding; 200 VAC/230 VAC configurations contain 4 A slow-blow fuse connected to transformer primary winding
Thermal Protection Integral transformer thermal switch is normally closed. Thermal switch opens when internal temperature of transformer reaches 110°C. Integral transformer thermal switch is normally closed. Thermal switch opens when internal temperature of transformer reaches 110°C.
Secondary Winding Configuration 28 VAC (40 VDC bus); 56 VAC (80 VDC bus); ±10 VDC, ±20 VDC, ±30 VDC, ±40 VDC 28 VAC (40 VDC bus); 56 VAC (80 VDC bus); 112 VAC (160 VDC bus)
+24 VDC Output 4 A max 4 A max