Shinkawa

SHINKAWA VM-21R REVOLUTION SIGNAL CONDITIONER

VM-21R

REVOLUTION SIGNAL CONDITIONER

(ex.1) 120P/R

1  2  0

(ex.2) When specifying without

an integral numbers.

Z  Z  Z

Specify No. of input P/R for the

shaft observed by sensor.

*2 Measurning by manual trigger is recommended in case that duty ratio of input signal is without 10 to 90% or input frequency is measured under 1 to 10Hz.

Input Transducer RD SERIES , FK SERIES , VK SERIES, MS SERIES

Input Resistance 50kΩ(Model Code No. of input transducer“D),5kΩ(Model Code No. of input transducer“J”)

Input Frequency Min.Input frequency:0.01Hz , Max.Input frequency:10kHz , Min pulse width:50μs

Minimum input voltage 2Vp-p

Hysteresis 1Vp-p , 5Vp-p

Output(isolated) 1 to 5VDC(output resistance:250Ω) or 4~20mADC(permissible load resistance:600Ω or less)

Measuring Range See Model Code No. above

I/O Conversion Accuracy ±1% of F.S. at 25°C, ±2% of F.S. at 0~50°C

Buffered Output Model Code No. of input transducer“D” : Approx. –2 to –22VDC

Model Code No. of input transducer“J” : Approx. . –10 to –10VDC

Pulse Output VL:-1 to +1V,  VH:4 to 6V

Trigger level setting*2 Automatic(trigger level is adjustable by internal trigger level V.R.)

Power Supply Output -24VDC,approx.30mA(for Model Code No.of input transducer“D”)

Burn-down Function 4 to 20mADC (1 to 5VDC) output to go to less than 0.8mADC(0.2VDC)

SupplyPermissible Voltage 24VDC±10% or 85~264VAC/DC (50/60Hz)

Power Consumption 24VDC:6.0W,  100-240VDC:6.0W,  100-240VAC:10VA

Insulation Resistance 100MΩ minimum at 500VDC between input-output-power-GND mutually

Withstand Voltage 2000VAC for one minute between input-output-power-GND mutually.

(With VM-21H: 1.000VAC between output-GND)

Operating Temperature /

Relative Humidity 0~50°C / 10~90%RH(no condensation)

Casing Material(color) Modified polyphenylene oxide(black)

Weight Approx. 110g(0.37lb)

CE Marking Only as for 24VDC power supply specifications.