SHINKAWA VM-702B ABSOLUTE VIBRATION MONITOR MODULE
VM-702B ABSOLUTE VIBRATION MONITOR MODULE
INPUT
Input system : 2systems
Input system Channel combination : A: Ch1. Ch2 B: Ch3. Ch4
Input impedance : Approx. 50kΩ
INPUT TRANSDUCER
Ch1 : VK-202A or FK-202F
Ch2 : CV-86 or CV-88
Ch3 : VK-202A or FK-202F
Ch4 : CV-86 or CV-88
SYNCHRONIZED SIGNAL SOURCE
VM-741B : Input via internal mother board.
OUTPUT
Indicators : OK LED (Green)
When channel is normal : ON, When alarming : Flashing
Monitor output : Location : BNC (Front) and connector (Back)
Ch1 or Ch3 : BUFF*1
Ch2 or Ch4 : BUFF, SEIS, ABS can be selected.*1
Output impedance : 100Ω
Output current : Max 5mA
Measurement value :
Combination Measurement value
Ch1. Ch3 Ch2. Ch4
1 REL *1 ABS *1
2 REL *1 SEIS *1
3 SEIS *1 ABS *1
*1 BUFF : Buffer signal
Input signal from a transducer is output via buffer amplifier.
REL : Relative vibration
SEIS : Seismic vibration
The signal is converted from velocity signal to displacement signal.
(787mV/100µm)
ABS : Absolute vibration
The signal is subtracted SEIS (Seismic vibration) on Ch2 or Ch4
from the input signal on Ch1 or Ch3 (Relative vibration).
(787mV/100µm)
Recorder output : Voltage or current output proportional to measurement
value.
Measurement value of each channel can be assigned to
any output channel of its own module.
Number of output points : 4 points
Output range : 1 to 5V, 4 to 20mA,
0 to 5V, 0 to 10V
I/O conversion accuracy : ±3% of F.S. at 25°C *2
±5% of F.S. at 0°C to 65°C *2
Max. load resistance : 600Ω (current mode)
Output impedance : Approx. 500Ω (voltage mode)
Insulation resistance : 10MΩ at 100VDC
Burnout function : Downscale 0%
Downscale 0mA / 0mV
Transducer power supply
Proximity transducer : -24VDC/25mA Max.
Piezoelectric transducer : +24VDC/4mA
(constant current)
Contact output : Number of relay : 6points (logic changeable)
Contact type : Dry contact (SPDT)
Enagization method : Normally de-energized or
Normally energized field changeable
Contact capacity : 250VAC/5A, 30VDC/5A
OUTPUT
Output to analysis software (When “/ALY” is requested)
Dynamic data : Synchronous waveform, Asynchronous
waveform
Static data : Amplitude (0.5X, 1X, 2X, nX(n=0.01 to
8.00), Not-1X, S(p-p) max)
Phase (0.5X, 1X, 2X, nX(n=0.01 to
8.00))
Rotation speed
Refer to the specification sheet of
VM-773B infiSYS ANALYSIS VIEW.
*2 At calibrate frequency.
ALARM
Alarm set point : Vibration monitoring
2 points (DANGER, ALERT), from 0 to 100% of
monitor range, field changeable
Alarm set accuracy : Vibration
±(0.2% of F.S.+1digit) or less at 25°C
Alarm set repeatability : ±1digit or less at 25°C
Alarm delay time : 0 to 99sec (0.1 sec step, field changeable)
Alarm reset : AUTO-RESET or SELF-HOLD field changeable.
Alarm bypass function : Block off alarm output (DANGER)
VIBRATION (OVER ALL) MONITORING
Recommend monitoring range
: 100 to 1000µm
Accuracy : ±2% of F.S. at 25°C *3
±3% of F.S. at 0°C to 65°C *3
HPF : 10Hz to 100Hz (-3dB), field changeable. *4(4 pole)
9.5Hz to 100Hz (-3dB), field changeable. *4(10 pole)
LPF : 200Hz to 1kHz (-3dB), field changeable. *4(4 pole)
Note) *3 At calibrate frequency.
*4 There is un-match combination.
(See “Vibration (Over All) Monitoring (Selection Table for Filter Set
Value P.5”.)
Sequence function : Used to prevent alarm output that is caused by
excessive vibration during machine startup. Block off the
DANGER/ALERT alarm, or switch the alarm setup value
to another number magnified by setup number.
Sequence Setup : Block off
1 to 10 (0.1 step, field changeable)
Suppression function : If the vibration value is less than the setup value,
this function is forced to suppress the measured
vibration value and recorder output.
*5 Suppression Setup Value: 0 to 5%
( 0.1% step, field changeable)
ANALYSIS FUNCTION (When “/ALY” is requested)
Amplitude accuracy : Overall 0.5X, 1X, 2X, nX(n=0.01 to 10.00), Not-1X
: ±3% of F.S. at 25°C
±5% of F.S. at 0°C to 65°C
(for machine speed less than 30000r/min)
S(p-p) max : ±5% of F.S. at 25°C
±7% of F.S. at 0°C to 65°C
Phase accuracy : 0.5X, 1X, 2X : ±3 deg. of of F.S. at 25°C
±6 deg. of F.S. at 0°C to 65°C
ENVIRONMENTAL CONDITION
Operating temperature : 0 to +65°C
Operating temperature at explosion proof construction
: 0 to +60°C
Storage temperature : -30 to +85°C
Relative humidity : 20 to 95%RH (non-condensing)
Power Consumption
Module : Less than 15W
MATERIAL AND FINISH
Face plate : ABS (Black)
Sheet : Polyester tough top (Gray)
Base plate : Alminium alloy (Silver)
MASS
Body : Max. 1.0kg (2.2lb)
ACCESSORY SPECIFICATION CODE / IDENTIFIED BY TB□
Code Accessory Quantity
(Part Code)
/TB1 Transducer input terminal block plug(15pin)
FRONT-MC-1.5/15-STF-3.81 (PHOENIX CONTACT)
2pieces *7
(7072NAB)
Recorder output terminal block plug(6pin)
FRONT-MC-1.5/6-STF-3.81 (PHOENIX CONTACT)
2pieces *7
(7072NAC)
Contact output terminal block plug(18pin)
FRONT-MC-1.5/18-STF-3.81 (PHOENIX CONTACT)
1piece
(7072NAA)
/TB2 Contact output terminal block plug(18pin)
FRONT-MC-1.5/18-STF-3.81 (PHOENIX CONTACT)
1piece
(7072NAA)
Note) *6 D-sub plugs and hoods are not included in this code. Please make
necessary arrangement separately, if required.
*7 When individually ordering specify the parts code, it is require to arrange
for a necessary amount.
INPUT
Monitor range : Ch1 0 to 200µm pk-pk (REL)
Ch2 0 to 200µm pk-pk (ABS)
Ch3 0 to 200µm pk-pk (REL)
Ch4 0 to 200µm pk-pk (ABS)
Input transducer : VK-202A (non-intrinsic safety)
CV-86 (non-intrinsic safety)
Input system : 2systems
Input impedance : 50kΩ
FILTERING
Low cut-off frequency : 10Hz (4 pole)
High cut-off frequency : 1kHz
OUTPUT
Recorder output : 4 to 20mA (4mA at the burnout)
Monitor output : Ch1 BUFF
Ch2 BUFF
Ch3 BUFF
Ch4 BUFF
ALARM
DANGER set point : 160µm
ALERT set point : 120µm
OK set point : Ch1 and Ch3 -1.4V (Low), -18.8V (High)
Ch2 and Ch4 2.1V (Low), 22.0V (High)
Alarm delay time : 3sec (DANGER, ALERT)
Alarm reset : AUTO-RESET
CONTACT OUTPUT
Contact (RELAY1) : DANGER-1
Contact (RELAY2) : ALERT-1
Contact (RELAY3) : OR logic (NOT-OK-1 / NOT-OK-2)
Contact (RELAY4) : DANGER-3
Contact (RELAY5) : ALERT-3
Contact (RELAY6) : OR logic (NOT-OK-3 / NOT-OK-4) :
Enagization method : Nomally de-energized
OTHERS
Sequnce set value : 1
Suppression set value : 0%
First out : OFF
Timed OK channel defeat : ON
Burnout : Downscale 0%
Alarm Contact Operation
Default Value
Specification
Contact type Enagization method Power OFF
Power ON
Normal state Alarm state
N.O. contact
NORMALLY DE-ENERGIZED OPEN OPEN CLOSE
NORMALLY ENERGIZED OPEN CLOSE OPEN
N.C. contact
NORMALLY DE-ENERGIZED CLOSE CLOSE OPEN
NORMALLY ENERGIZED CLOSE OPEN CLOSE
! WARNING
Some functions may not be available with old version.
For details, please refer to “infiSYS Family Improvement
Information” (6H16-011).