SHINKAWA VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE
VM-701B VIBRATION / DISPLACEMENT
MONITOR MODULE
Model Code / Additional Spec. Code
、VM-701B /PM /AL
Phase Marker Function Analysis Function
0 Without 0 Without
1 With Y With
(When “/ALY” is requested)
/NB1 /CS1 /CS2 /TRP /TB
Non-incendive Monitor Function Analysis Function Tropical spec. I/O terminal block for
CSA C/US: Custom setup Custom setup 1 VM-761B instrument rack
1 Class , Division 2, (When “/ALY” is requested) 2 VM-762B instrument rack
Groups A,B,C and D
*1 Please check the input rated power of the rack. Refer to the
specification sheet, “VM-75□B POWER SUPPLY MODULE
(Specification No. 31109E1.1 or later).
INPUT (VIBRATION/DISPLACEMENT)
Input points : 4point
Input impedance : Approx. 50kΩ
(Current signal input: Approx. 250Ω)
INPUT TRANSDUCER (VIBRATION/DISPLACEMENT)
Displacement vibration input : FK-202F, FK-452F, FK-302F, VK-202A,
VK-452A, VK-202P, VK-302P, VC-020
Velocity vibration input : CV-88, CV-87, CV-86
Acceleration vibration input : CA-302, CA-72
Displacement input : FK-202F, FK-452F, FK-302F, FK-602F, FK-143F,
FK-263F
VK-202A, VK-452A, VK-302P, VK-602P,
VK-143P, VK-263P, VC-253
Other input : VM-21P
Voltage signal (Input range:-10V to +10V)
Current signal (Input range:4mA to 20mA)
INPUT (Phase Marker) (When “/PM1” is requested)
Input point (tachometer) : 1point
Input impedance : 50kΩ
Input voltage range : Less than 50Vp-p
Min. pulse width : 50μsec
Hysterics set value : 1V, 2V, 5V
Maximum rotation speed : 60,000rpm
INPUT TRANSDUCER (Phase Marker) (When “/PM1” is requested)
Proximity transducer : FK-202F
RD-05A
SYNCHRONIZED SIGNAL SOURCE
Another VM-701B or VM-706B : input via transducer input terminal.
VM-741B : input via internal mother board.
OTHERS
OUTPUT
Indicators : OK LED (Green)
When channel is normal : ON, When alarming : Flashing
TRG LED (Yellow)
When rotational pulse is not detected : ON
When rotational pulse is detected : Flashing
Monitor output : Input signal is output via buffer amplifier.
Location : BNC (Front) and connector (Back)
Output impedance : Approx. 100Ω (Max.5mA)
Pulse output : Shaped pulse signal is output via a buffer amplifier.
Location : BNC (Front)
Output impedance : Approx. 100Ω (Max. 5mA)
Signal level : 0V (VOL), 5V (VOH)
Synchronized signal output
: Shaped pulse signal is output via a buffer amplifier.
Location : Terminal (Back)
VM-761B : D5/D6
VM-762B : 15pin D-SUB 13, 14
Output impedance : Approx. 100Ω (Max.5mA)
Signal level : 0V (VOL), 5V (VOH)
Recorder output : Voltage or current output proportional to measurement
value.
Measurement value of each channel can be assigned to
any output channel of its own module.
Number of output points : 4 points.
Output range : 1 to 5V, 4 to 20mA,
0 to 5V, 0 to 10V
I/O conversion accuracy : ±1% of F.S. at 25°C*2
±2% of F.S. at 0°C to 65°C *2
Max. load resistance: 600Ω (current mood)
Output impedance: Approx. 500Ω (voltage mood)
Insulation resistance: 10MΩ at 100VDC
Burnout function: Downscale 0%
Downscale 0mA / 0mV
Transducer power supply :
Proximity transducer : -24VDC±10% / 25mA Max.
Piezoelectric transducer : +24VDC±10% / 4mA
(constant current)
Contact output :
Number of relay : 6 points (logic changeable)
Contact type : Dry contact (SPDT)
Energization method
: Normally de-energized or
Normally energized field changeable.
Contact capacity : 250VAC/5A, 30VDC/5A
Output to analysis software (When “/ALY” is requested)
Dynamic data : Synchronous waveform, Asynchronous waveform
Static data : Amplitude (0.5X, 1X, 2X, nX (n=0.01 to 8.00),
Not-1X,S(p-p) max)
Phase (0.5X, 1X, 2X, nX (n=0.01 to 8.00))
Rotation speed
Refer to the specification sheet of
VM-773B infiSYS ANALYSIS VIEW.
Alarm set point : Vibration monitoring
2 points (DANGER, ALERT), from 0 to 100% of
monitor range, field changeable
Displacement monitoring
4 points (H-DANGER, H-ALERT, L-DANGER,
L-ALERT), from -50% to +50% of monitor range,
field changeable
Alarm set accuracy : Vibration, Displacement
±(0.2% of F.S.+1digit) or less at 25°C
Alarm set repeatability : ±1digit or less at 25°C
Alarm delay time : 0 to 99sec (0.1 sec step, field changeable)
Alarm reset : AUTO-RESET or SELF-HOLD field changeable.
Alarm bypass function : Block off alarm output (DANGER)
VIBRATION (OVER ALL) MONITORING
Rectification : Root Mean Square (RMS)
Peak-to-Peak (p-p)
Peak-to-Peak (p-p) rectification for low speed
Note)
・ Rectification is calculation method to convert vibration waveform to amplitude which may
be different from monitor range scale.
(Ex. p-p conversion scale by RMS rectification)
・ Refer to Table1 for rectification selection.
・ The peak rectification is recommended when high speed response time and true p-p
rectification are preferred. The RMS rectification is recommended when noise
resistance or runout inhibition are preferred.
(○:YES ×:NO)
Transducer Monitor Range (Parameter)
Rectification
RMS p-p p-p rectification
for low speed
Displacement
(VK, FK) Displacement Vibration (p-p) ○ ○ ○
Velocity
(CV)
Displacement Vibration (p-p) ○ ○ ×
Velocity Vibration (rms) ○ × ×
Velocity Vibration (peak) ○ × ×
Acceleration
(CA)
Velocity Vibration (rms) ○ × ×
Velocity Vibration (peak) ○ × ×
Acceleration Vibration (rms) ○ × ×
Acceleration Vibration (peak) ○ × ×
Table 1 Selection table for rectification
Root Mean Square (RMS)
Recommend monitoring range : 100 to 1000μm, 10 to 100mm/s, 1 to 20g
Accuracy : ±1% of F.S. at 25°C*3
±2% of F.S. at 0°C to 65°C*3
HPF : 2Hz to 1kHz (-3dB)*3 (4 pole)
9.5Hz to 100Hz (-3dB)*4 (10 pole)
LPF : 200Hz to 10kHz (-3dB)*4 (4 pole)
Peak-to-Peak (p-p)
Recommend monitoring range : 100 to 1000μm
Accuracy : ±1% of F.S. at 25°C*3
±2% of F.S. at 0°C to 65°C*3
HPF : 2Hz to 100Hz (-3dB)*4 (2 pole)
9.5Hz to 100Hz (-3dB)*4 (10 pole)
LPF : 500Hz to 1kHz (-3dB)*4 (4 pole)
Note) *3 At calibrate frequency.
*4 There is un-match combination.
(See “Vibration (Over All) Monitoring (Selection Table for Filter Set
Value P.6, 7”.)
Peak-to-Peak (p-p) rectification for low speed
Recommend monitoring range : 100 to 1000μm
Accuracy : ±3% of F.S. at 2Hz at 25°C
HPF : 0.2Hz (-3dB), (1 pole)
9.5Hz to 100Hz (-3dB) (10 pole)
LPF : 500Hz to 1kHz (-3dB), (4 pole)
Note)
・ Applicable, only for displacement transducer input and displacement vibration
measurement.
・ Basically, phase marker signal are required. When no phase marker signal is input, rise
time speed may be deteriorate at normal speed range.
・ Standard high-pass filter (4 pole, 2 pole) cannot be selected.
(See “Vibration (Over All) Monitoring (Selection Table for Filter Set Value
P.6, 7”.)
VIBRATION (OVER ALL) MONITORING
Sequence function : Used to prevent alarm output that is caused by
excessive vibration during machine startup. Block off the
DANGER/ALERT alarm, or switch the alarm setup value
to another number magnified by setup number.
Sequence Setup :Block off
1 to 10 (0.1 step, field changeable)
Suppression function
: If the vibration value is less than the setup value, this function is
forced to suppress the measured vibration value and recorder output.
*5 Suppression Setup Value: 0 to 5%
( 0.1% step, field changeable)
DISPLACEMENT MONITORING
Accuracy : ±1% of F.S. at 25°C
±2% of F.S. at 0°C to 65°C
Frequency response : Approx. 0.5Hz (-3dB)
Zero shift function : -50 to +50% of monitor range
Lamp angle (θ) : 4 to 90 degree
Type 1 Type 1
Type 2 Type 3
Operation function : Addition/Subtraction
Ch1 + Ch2, Ch2 + Ch3, Ch3 + Ch4
Ch1 – Ch2, Ch2 – Ch3, Ch3 – Ch4
Note)
・ When this monitor is used for intrinsically safe explosion proof construction, the OK
alarm set point may fall within the range, depending on the input transducer and the
specified monitoring range.
ANALYSIS FUNCTION (When “/ALY” is requested)
Amplitude accuracy : Overall 0.5X, 1X, 2X, nX (n=0.01 to 10.00), Not-1X
: ±3% of F.S. at 25°C
±5% of F.S. at 0°C to 65°C
(for machine speed less than 30000 r/min)
S(p-p) max : ±5% of F.S. at 25°C
±7% of F.S. at 0°C to 65°C
Phase accuracy : 0.5X, 1X, 2X : ±3 deg of rdg. at 25°C
±6 deg of rdg. at 0°C to 65°C