Eaton XN-312-GW-CAN Gateway modules
Download settings or retrieve metered and historical values via
the communications port.
14. Flexible user-configurable inputs and outputs for broader applica
tion.
15. Options for transition function control and monitoring on time
and/or current.
16. Emergency override function resets jogging limit functions and
clears thermal model bucket to permit restart with a time-tagged
event log. Unit uses a secured button; this function can be dis
abled.
17. Relay can be programmed while motor runs, and new settings
are all put into effect at once in a controlled fashion. Or, User can
set unit so programming is allowed only after motor stop.
1.3 Use of This Manual
This manual contains the following sections:
Section 1 – Introduction – Describes the upgrade changes
from the existing IQ-1000II to the MP-3000. including retrofit
and new features list.
Section 2 – Product Overview – Benefits, feature list, use of
manual, and list of options.
Section 3 – Specifications – Provides hardware specifics
Section 4 – Operator Panel – Describes the pushbuttons,
LEDs, display window, and security door on the MP-3000’s
faceplate, plus the different modes of operation and detailed
mode description tables.
Section 5 – Programming the MP-3000 – Gives specific guid
ance for selecting setting values.
Section 6 – Installation and Wiring – Outlines procedures for
the plant electrician to follow when installing and wiring the
| Metso | ITP 201 |
| Hirchmann | BRS30-16042T2T-STCZ99HHSES |
| Emerson | IC31224G01 |
| Emerson | IC31227G01 |
| WATLOW | DIN-A-MITE C |
| Emerson | IC31129G05 |
| Emerson | IC31132G02 |
| Emerson | 5X00605G01 |
| Emerson | 1X00884H01 |
| Emerson | IC31219G01 |
| Emerson | 5X00623G01 |
| Emerson | 5X00225G01 |
| ABB | 8990001-NK |
| Honeywell | 05701-A-0330 |
| Honeywell | 05701-A-0330 |
| Honeywell | 05701-A-03 |
| SAUTER | AVM234SF132 |
| Emerson | 5X00225G01 |
| Emerson | 1C31224G01 |
| Emerson | 1C31227G01 |
| Emerson | 1C31219G01 |
| Motorola | FLN3566A |
MP-3000.
Section 7 – Startup – Lists step-by-step procedures for ener
gizing the MP-3000 for the first time after installation.
Section 8 – Motor Thermal Protection Basics – Gives an
overview of how the hardware and software function to
gether to control, monitor, and protect the motor.
Section 9 – Application and Settings – Is intended as an aid
to the application engineer considering how and when to
apply the various features of the MP-3000.
Section 10 – Data Communications – Describes what is
needed for the MP-3000 to communicate with host com
puter systems.
Section 11 – Testing – Describes how to use the MP-3000
test functions and details recommended maintenance.
Section 12 – Troubleshooting – Provides information on how
to use the Operator Panel to recognize malfunctions. Also,
gives specific troubleshooting procedures.
Section 13 – Drawout Case Option – Describes installing and
using MP-3000 drawout case models.
When the User is familair with the basics of operating the MP-3000.
Tables 4.1 through 4.5 should be used as guides to program and
monitor the relay.
The following accessories and options are covered in other instruction
manuals:
Table 1.1 MP-3000 accessories and Options.
URTD module for
connecting RTDs
to MP-3000 (1)
IQ DC Power Supply,
100-150 Vdc
INCOM PONI (IPONI)
Ethernet PONI (EPONI)
Other PONI Types
I.L. 17367
I.L. 17286
I.L. 17547
I.L. 17560
Consult Eaton distributor or
Eaton.com website
DPONI Types
(1)
I.L. 17559
This MP-3000 instruction manual (IM) gives all basic informa
tion on installing the URTD module.
NOTE: Some manuals will be supplied electronically on the CD
shipped with the MP-3000.