The advantage of the old 6581 is that there is a reverse enginered schematics available, if needed for a repair.
As a downside the displays are often dim and a replacement is a bit tricky.
A know weak point for the 6581 is the rather large current spike from AZ switching – this can be an issue with some signal sources.
Another point is that ACAL may not be fully accurate for the highest resistor ranges.
So the specs there may be a bit overly optimistic.
Quite a few of the old meters also have a relay power saving mode not working right
that can cause some thermal EMF error that can effect the lower voltage ranges – this is fixable at least.
The 6581T tends to have a rather poor factory calibration that causes quite some INL error
– so while the ADC is essentially the same as with the full version, the linearity is not that great for the T version.
There may be ways to correct this, but it is extra effort and may need extra instruments (e.g. cal source).
MITSUI ENGINEERING MAG-1A ELECTRONIC CONTROLLER CONTROL PANEL GCU-1A ENGINE SPEED
SPECTRA-TEK SENTINEL 500 PROCESSOR BOARD FLOW COMPUTER
SIEMENS 7SJ8042-5EB20-1FB0/CC OVERCURRENT PROTECTION RELAY
MITSUI ENGINEERING BMS-1500 ELECTRONIC GOVERNOR/ENGINE REMOTE CONTROL SYSTEM PAN
MITSUI ENGINEERING BMS-1500 ELECTRONIC CONTROLLER/MOTOR REMOTE CONTROL SYSTEM PAN
SIEMENS 7SJ8042-5EB20-1FB0/CC OVERCURRENT PROTECTION RELAY
SEW EURODRIVE MOD32A/MM30D-503-00/Z38G DRIVE INTERFACE 3.0 KW 18215068
SPERRY MARINE 0395618072274 DOPPLLER SPEED LOG SYSTEM SRD-331
TELEMECANIQUE ALTISTART 48 ATS48D75Y SOFT STARTER 75A
ALLEN BRADLEY CAT 140G-M6X3 CIRCUIT BREAKER 600A BE31025582
ABB PMS10V08 PROCESSOR MODULE 3BSE008373R1 3BSC980006R283
ABB SACE E1 AIR CIRCUIT BREAKER 1250A OCR SACE PR111/P
SEW EURODRIVE MOD32A/MM30D-503-00/Z38G DRIVE INTERFACE 3.0KW 18215068
SPERRY MARINE 0395618072274 DOPPLER SPEED LOG SYSTEM SRD-331
BOTEST ASYS SCIV TEST UNIT FLASH CONTROL UNIT FCU-002 0030
BOTEST ASYS SCIV TESTER FLASH CONTROLLER FCU-002 0030
DAIHATSU MDP-REV SPEED SWITCH 00853-011 24Vdc 3.2W MEIYO ELECTRIC MARINE DIESEL
WOODWARD EASYGEN 1400 AMF CONTROLLER 8440-2269 REV D
JRC JUE-251 CMZ-124
EATON CUTLER HAMMER FP5200-00 FEEDER PROTECTION RELAY FP-5000
PRO-FACE LT3301-L1-D24-C TOUCH PANEL HMI 24VDC OPERATOR INTERFACE 3583401-14
EATON CUTTING HAMMER FP5200-00 FEEDER PROTECTION RELAY FP-5000
FUJI ELECTRIC PHA98004-EA0YV STRIP CHART RECORDER 100-240V
AUTOMATION DIRECT FPM-170T/24 LCD MONITOR
SIEMENS 3WX3141-3JC02 OVERCURRENT RELEASE TRIP UNIT WITH GROUND FAULT
AYDIN DISPLAYS FPM-190T REV B 19 INCH TCH MONITOR
HYUNDAI 4AP41 POWER TRANSFORMER TI16695.1 | AHB527-10 INDUSTRIAL RECTIFIER TRANS
HYUNDAI TI16695.1 CONTROL TRANSFORMER 4AP40 | INDUSTRIAL POWER TRANSFORMER A0388
MERLIN GERIN ST 418 S MASTERPACT CONTROL UNIT TU1547 110 1200A
HYUNDAI 4AP41 MAINS TRANSFORMER TI16695.1 | AHB527-10 INDUSTRIAL RECTIFIER TRANS
Operation
In addition to amplifier analysis, a variety of display modes are available, such as
– Overlay display,
– Comparison with memory contents,
– Display of two independent graphs (split screen),
– Power meter function,
– Use of multiple markers,
– Normalized and direct readout of transmission loss and
– Automatic bandwidth analysis (e.g. measurement of half-value widths based on RMS and envelope methods),
– Curve fitting over the IEC/IEEE bus and many other features facilitate operation of the analyzer and simplify analysis.
Measurement time is 0.8 seconds for a span of 200 nm and varies with the span.
Broadband light sources with a resolution of 5 nm have the highest sensitivity,
while narrowband light sources (lasers) can be reliably analyzed down to the noise level even with a narrow resolution bandwidth.
The normalization function combined with the white light source allows direct measurement of transmission and loss characteristics of filters and fibers.