HIRSCHMANN

HIRSCHMANN MSM20-M2M2M2M2TZ9HH9E99.9.99

Product: MSM20-M2M2T1T1SY9HH9E99.9.99

Configurator: MSM – Media Module for MSP configurator

Configurator Description

The variety of transmission media and range of connector versions ensure an optimum degree of flexibility and application coverage. Any combination of the

hot-swappable media modules may be used to attain the desired port density/type on a MICE Switch Power switch. The sole limitation is the number of media

module slots on a switch (one media module per slot).

Technical Specifications

Product description

Description Fast Ethernet Media Module for PowerMICE Switches (MSP) , Standard Ethernet media modul

Configurator Part Number 942077999

Port type and quantity Port 1: 100BASE-FX, MM-SC; Port 2: 100BASE-FX, MM-SC; Port 3: 10/100BASE-TX, RJ45; Port 4: 10/100BASE-TX, RJ45

Network size – length of cable

Twisted pair (TP) Port 3: 0-100 m Port 4: 0-100 m

Multimode fiber (MM) 50/125 Port 1: 0-5000 m, 8 dB Link Budget at 1300 nm, A=1 dB/km, 3 dB Reserve, B = 800 MHz x km Port 2: 0-5000 m, 8 dB Link Budget at 1300 nm, A=1 dB/km, 3 dB Reserve, B

= 800 MHz x km

Multimode fiber (MM) 62.5/125 Port 1: 0 – 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB Reserve, B = 500 MHz x km Port 2: 0 – 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB

Reserve, B = 500 MHz x km

Power requirements

Operating voltage Power supply via the backplane of the MSP switch

Power consumption 4 W

Power output in Btu (IT) h 14

Software

Diagnostics LEDs (power, mode, link/data)

Ambient conditions

Operating temperature 0-+60 °C

Storage/transport temperature-40-+85 °C

Relative humidity

(non-condensing) 5-95 %

Mechanical construction

Dimensions 38 mm × 133 mm × 118 mm

Weight 201 g

Mounting Backplane

Protection class IP20

Mechanical stability

IEC 60068-2-6 vibration 5 Hz – 8.4 Hz with 3.5 mm amplitude; 8.4 Hz-150 Hz with 1 g

IEC 60068-2-27 shock 15 g, 11 ms duration

EMC interference immunity

EN 61000-4-2 electrostatic

discharge ± 4 kV contact discharge; ± 8 kV air discharge

EN 61000-4-3 electromagnetic

field

EN 61000-4-4 fast transients

(burst)

EN 61000-4-5 surge voltage

EN 61000-4-6 conducted

immunity

EMC emitted immunity

10 V/m (80 MHz-3000 MHz)

± 2 kV power line; ± 4 kV data line

power line: ± 2 kV (line/earth), ± 1 kV (line/line); data line: ± 1 kV (line/earth)

10 V (150 kHz-80 MHz)

EN 55022

EN 55032 Class A

FCC CFR47 Part 15

FCC 47CFR Part 15. Class A

发表回复