Schneider Electric GUTOR OP2552 Three-phase Power Connection Board Assembly
Schneider Electric GUTOR OP2552 (and variant OP2552AB) is a heavy-duty Three-phase Power Connection Board Assembly designed specifically for high-capacity Gutor PEW, WXW, and SDC industrial uninterruptible power supplies (UPS) and industrial rectifier systems.
Positioned at the primary electrical interface boundary inside the cabinet, the OP2552 handles the direct termination, heavy-current tracking, analog routing, and surge suppression of incoming or outgoing three-phase power lines. It acts as the physical and electrical shield between raw power distribution buses and the delicate, low-voltage control electronics stack.
Technical Parameter Table
The OP2552 is manufactured to withstand high-energy transients and heavy continuous current paths.
| Parameter | Specifications |
| Manufacturer | Schneider Electric / Gutor Electronic LLC (Switzerland) |
| Component Type | Three-phase Power Connection Board Assembly |
| Model / Part Number | OP2552 / 0P2552AB (P/N: 640-2552) |
| System Compatibility | Gutor PEW (3-Phase UPS), WXW Inverters, and High-Capacity SDC Rectifiers |
| Electrical Configuration | Three-Phase Input/Output routing with integrated ground paths |
| Primary Function | Power signal termination, high-energy snubbing, and sensory distribution |
| Protection Circuitry | Onboard metal oxide varistors (MOVs) and transient voltage suppression arrays |
| Environmental Protection | Full heavy-duty industrial conformal coating against humidity and chemical gasses |
| Weight | Approximately 1.22 kg (Heavy copper clad design for thermal distribution) |
Unique Product Description
The GUTOR OP2552 serves as the primary electrical landing hub within industrial-grade double-conversion power systems. Operating in extreme spaces like oil refineries or substations, raw three-phase utility power frequently contains high-voltage switching surges, phase noise, and severe lightning transients.
The OP2552 features a specialized heavy copper PCB architecture that handles high thermal dissipation while acting as a hardware-level filter. It attenuates raw grid-side noise through high-energy snubber circuits, cleanly routing scaled voltage and current sensing lines down to downstream acquisition modules like the OP6285A. This clean isolation secures consistent power data delivery without exposing internal microprocessors to hazardous main line voltage steps.
Product Advantages and Features
Heavy Copper Clad PCB Construction: Built with thick, multi-layered copper traces designed to withstand the continuous thermal cycles of heavy-duty industrial installations.
Integrated Transient Suppression: Features high-capacity, onboard surge protection components that absorb volatile grid spikes before they penetrate the internal system busbars.
Pre-Engineered Sense Breakouts: Includes isolated terminal interfaces that securely drop high-phase voltages down to safe micro-levels for real-time monitoring and processing.
Corrosive Air Resiliency: The assembly is entirely coated with advanced conformal insulation, stopping track corrosion or short circuits caused by moisture, salt mist, or ambient sulfur gases.
Related Models & Same-Series Variations
The OP2552 interfaces directly with Gutor’s primary internal power distribution blocks and control cards:
GUTOR OP2552 / OP2552AB: (Current Standard) The core three-phase power connection assembly.
GUTOR OP6285A: Power Signal Acquisition Board (the card that processes the scaled analog voltage/current signals routed from the OP2552).
GUTOR OP6280: Basic Signal Board (manages auxiliary contact loops and breaker state tracking).
GUTOR OP2456 / OP2456B: Main Control CPU Module Boards (the central systems tracking grid data extracted by the connection board).
Application Cases
Petrochemical and Offshore Platforms: Mounted inside cabinet footprints exposed to high coastal salt moisture and structural vibration to secure primary three-phase utility terminations.
Nuclear and Heavy Utility Infrastructure: Implemented within Class 1E backup systems to route stable three-phase input feeds directly to rectifier firing circuits during localized grid drops.
Heavy Steel and Chemical Smelting: Deployed in high-energy unconditioned environments to protect the central UPS controller from massive electrical noise created by localized arc furnaces or giant motors.
Installation and Maintenance
Absolute LOTO Isolation Required: Because the OP2552 anchors raw three-phase grid lines, technicians must perform a complete Lockout/Tagout (LOTO) procedure on both input mains and internal battery lines before servicing or touching this card.
Torque Spec Compliance: When securing phase line lugs or terminal wire screws onto the board, technicians must follow Gutor’s specific torque ratings to prevent localized resistance heating under continuous high loads.
De-energized Board Replacement: The OP2552 is a core power landing interface and cannot be hot-swapped under any circumstances. Ensure the panel is completely discharged (verifying zero voltage on DC buses