Beckhoff Polaris CP7011-1002-0010 operator operator HMI display 30.5 cm
Beckhoff Polaris CP7011-1002-0010 operator operator HMI display 30.5 cm
Product Description
Appropriate Use
The CP70xx Control Panel is designed for industrial application in machine
and plant engineering. An aluminum housing contains a TFT display,
touch-screen/pad (optional), and a PC keyboard (optional). The panel is
installed via the 4 mounting holes in the backplane or the mounting arm
system adapter (optional).
The Control Panel must not be used where there is a risk of
explosion. CP-Link connection
The CP-Link connection allows data transmission between Control Panel
and CP-Link-Interface card of the Industrial-PC and providing the Control
Panel with the supply voltage. Two coaxial cables are required, the cable
length between Control Panel and Industrial-PC amounts to at most 100 m.
The red point on the CP-Link card and the red marking at the coaxial cable
or at the bend protection allow better orientation while connecting the
CP-Link cable with BNC-connectors
C9900-K114 – Length 3 m (cable type Belden H155. bend radius 35 mm)
C9900-K115 – Length 5 m (cable type Belden H155. bend radius 35 mm)
C9900-K116 – Length 10 m (cable type Belden H155. bend radius 35 mm)
C9900-K117 – Length 15 m (cable type Belden H155. bend radius 35 mm)
C9900-K118 – Length 20 m (cable type Belden H155. bend radius 35 mm)
C9900-K119 – Length 30 m (cable type Aircell7. bend radius 25 mm)
C9900-K120 – Length 35 m (cable type H2000FLEX, bend radius 50 mm)
C9900-K121 – Length 50 m (cable type H2000FLEX, bend radius 50 mm)
C9900-K122 – Length 65 m (cable type H2000FLEX, bend radius 50 mm)
C9900-K123 – Length 70 m (for easy installation at the PC and the mounting
arm: 1 m Aircell7 + 61 m Cellflex + 8 m Aircell7)
C9900-K124 – Length 80 m (for easy installation at the PC and the mounting
arm: 1 m Aircell7 + 71 m Cellflex + 8 m Aircell7)
C9900-K125 – Length 90 m (for easy installation at the PC and the mounting
arm: 1 m Aircell7 + 81 m Cellflex + 8 m Aircell7)
C9900-K126 – Length 100 m (for easy installation at the PC and the mounting
arm: 1 m Aircell7 + 91 m Cellflex + 8 m Aircell7)
Dimensions a b t A B
CP7009 6.5“ Display 267.9 173 38 241.9 149
CP7000 10“ Display 353.8 308.3 27.5 327.6 280.7
CP7001 12“ Display 353.8 326.3 27.5 327.6 303.7
CP7002 15“ Display 426 395 28.5 399.8 367.4
M6 screw thread
Control Panel CP701x
Dimensions a b t A B
CP7019 6.5“ Display 267.9 213 38 241.9 189
CP7010 10“ Display 353.8 308.3 27.5 327.6 280.7
CP7011 12“ Display 353.8 326.3 27.5 327.6 303.7
CP7012 15“ Display 426 395 28.5 399.8 367.4
Control Panel CP702x
Dimensions a b t A B
CP7029 6.5“ Display 336 213 38 310 189
CP7020 10“ Display 406 308.3 27.5 374.8 280.7
CP7021-0000/1 12“ Display 406 308.3 27.5 374.8 280.7
CP7021-0002 12“ Display 439.8 308.3 27.5 408.6 280.7
CP7022 15“ Display 515 370.2 28.5 483.8 342.6
Control Panel CP703x
Dimensions a b t A B
CP7030 10“ Display 403.2 368.2 27.5 372.15 340.6
CP7031-0000/1 12“ Display 406 370.2 27.5 379.8 342.6
CP7031-0002 12“ Display 426 370.2 27.5 399.8 342.6
CP7037 12” Display 426 370.2 27.5 399.8 342.6
CP7032 15“ Display 483 410.2 28.5 458.8 387.6
Functional description
The Control Panel does not have its own mains power switch. As soon as
the power supply is switched on the control panel is activated.
Control software, as typically applied in Control Panels, enables the
assignment of different rights to all users. A user who is not entitled to shut
down the software may not switch off the Control Panel as an attempt to
shut it down when the software is running could result in the loss of
software data on the Compact Flash memory card.
If the control panel is shut down while the software is writing a file onto the
Compact Flash memory card, the file will be destroyed. Control software
typically writes something to the CF memory card every few seconds, so
that the probability of causing damage by switching off while the software is
running is very high.
The Control Panel’s membrane keypad may only be actuated by fingertips.