Technical Data for AKD-xzzz06

Technical data fortheregencircuit depends onthedrivetypeandthemains voltage.

Supply voltages, capacitances, andswitch-onvoltages areall nominal values.

Brakecircuit

Type

Supply voltage

Rateddata Units

120V/ 240V

AKD-xzzz06

all types

Type

AKD-x00306

Switch-onthreshold of regencircuit V

Switch-off threshold of regen circuit V

Maximumregenduty cycle %

SC1R06260

Rateddata Units

120V/ 240V

External regen resistor Ohm

Maximumcontinuous regenpower, external resistor kW

Peak regenpower, external (1s) kW

Absorption energy incapacitors (+/- 20%) Ws​

DCBusCapacitance µF

AKD-x00606

External regen resistor Ohm

Maximumcontinuous regenpower, external resistor kW

Peak regenpower, external resistor(1s) kW

Absorption energy incapacitors (+/- 20%) Ws

DCBusCapacitance µF

AKD-x01206

Internal regen resistor Ohm

Continuous power, internal resistor W

Peak regenpower, internal resistor (0.5s) kW

External regen resistor Ohm

Maximumcontinuous regenpower, external resistor kW

Absorption regen power, external resistor (1s) kW

Storeable energy incapacitors (+/- 20%) Ws

DCBusCapacitance µF

AKD-x02406 Internal regenresistor Ohm

Continuous power, internal resistor W

Peak regenpower, internal resistor (0.5s) kW

External regen resistor Ohm

Maximumcontinuous regenpower, external resistor kW

Peak regenpower, external resistor(1s) kW

Absorption energy incapacitors (+/- 20%) Ws

DCBusCapacitance

Switch-on and Switch-off Behavior

This chapterdescribes theswitch-onandswitch-off behaviorof theAKD.

Behavior of “holding brake” function

Drives withanenabledholdingbrakefunctionhaveaspecial timingforswitchingonandoff theoutput stage(=>

p. 93). Events that removetheDRV.ACTIVE signal triggertheholdingbraketoapply. As withall electronic cir

cuits, the general rule applies that there is a possibility of the internal holding brake module failing. Personnel

safety, e.g. with hanging load (vertical axes), requires an additional mechanical brake which must besafely oper

ated, for exampleby asafety control.

If velocity drops below threshold CS.VTHRESH ortimeout occurs duringastopprocedure, thebrakeis applied.

Behavior when undervoltage condition is present

Thebehaviorinanundervoltageconditiondepends ontheVBUS.UVMODE setting.

VBUS.UVMODE DCBusUndervoltageMode.ConsulttheAKD UserGuideforconfiguringtheparameter.

0 ThedrivewillreportaF502undervoltagefaultanytimeanundervoltageconditionoccurs.

1 (default)

Thedrivewill report a warningn502if not enabled. Thedrivewill report afault if thedrive is

enabled whentheconditionoccurs, oranattempt is madetoenablewhileanundervoltage

condition occurs.

Safety function STO

Withthepersonnel safefunctionSTO, thedrivecanbesecuredonstandstill usingits internal electronics sothat

evenwhenpoweris beingsupplied, thedriveshaft is protectedagainst unintentional restart. Thechapter“Safe

TorqueOff (STO)”describes how tousetheSTOfunction(=> p. 54)