OMRON K3HB-HTA-DRT1 Temperature Panel Meter

OMRON K3HB-HTA-DRT1 Temperature Panel Meter

Observe the following precautions to ensure safety.

(1) Be sure to confirm the name and polarity for each terminal before performing wiring.

Incorrect wiring may result in burning of or other damage to internal components.

(2) Use a power supply within the specified voltage range.

Use the product within the rated load.

(3) Tighten the screws on the terminal block securely.

The recommended tightening torque is 0.43 to 0.58 N·m.

Loose screws may result in product failure or malfunction.

(4) Do not connect anything to unused terminals.

(5) Ensure that the rated voltage is achieved no longer than 2 s after turning the power ON.

(6) Output turns OFF when the mode is changed or settings are initialized. Take this into

consideration when setting up the control system.

(7) Install an external switch or circuit breaker and label them clearly so that the operator can

quickly turn OFF the power.

Precautions for Correct Use

●General Precautions

(1) Do not use the product in the following locations.

• Locations subject to direct radiant heat from heating equipment

• Locations where the product may come into contact with water or oil

• Locations subject to direct sunlight

• Locations where dust or corrosive gases (in particular, sulfuric or ammonia gas) are

present

• Locations subject to extreme temperature changes

• Locations where icing or condensation may occur

• Locations subject to excessive shocks or vibration

(2) Provide sufficient space around the product for heat dissipation.

(3) Ensure that the rated voltage is achieved no longer than 2 s after turning the power ON.

(4) Allow the product to operate without load for at least 15 minutes after the power is turned

ON.

(5) To prevent static electricity, do not touch the slits or the terminals while the power is

turned ON.

(6) Do not place heavy loads on the product that would cause it to deform or deteriorate.

●Mounting and Wiring

(1) Mount to a panel between 1-mm and 8-mm thick.

(2) Install the product horizontally.

(3) Use crimp terminals appropriate for the screw size (M3)

PPC322BE01  HIEE300900R000 Control unit motherboard ABB
6181P-15TPXPSS performance model unit   Allen Bradley
2711-T6C1L1 Allen-Bradley PanelView 600   Standard Operator Terminal
PXIe-4143 NI PXI Source Measure Unit
TPMC866-11R TEWS 8 Channel Serial   Interface
330130-040-12-RU Bently Nevada Extension   Cable
330101-00-24-10-02-05 3300 XL 11 mm Probe   Bently Nevada
330101-00-20-10-02-RU 3300 XL 11 mm Probe   Bently Nevada
3500/22M-01-01-R0 Transient Data   Interface Module Bently Nevada
3500/42M-04-00 Proximitor Monitor Bently   Nevada
330500-02-RU Velomitor Piezo-velocity   Sensor
330102-00-24-20-12-05 Bently Nevada 3300   XL 8 mm Probe
3500/42-09-00-R0 Proximitor Seismic   Monitor Bently Nevada
KJ4001X1-BE1 12P0818X072 REV:L Redundant   Serial Interface Card EMERSON

发表回复

您的邮箱地址不会被公开。 必填项已用 * 标注