Power magnetics are used in the system to provide isolation, voltage transformation,
and impedance. These include:
The isolation transformer feeds 3-phase ac input power to the Static Starter power
converters. The transformer provides isolation from the ac system bus and provides
the correct voltage and phasing to the static converters.
Optional ac line reactors are
available.
The dc link reactor is an air core inductor that provides inductance to smooth the
current delivered by the static power converters.
Various circuit breakers and motor operated disconnect switches are used in the
system to make the appropriate power connects required for a static start operation.
The 52SS is a circuit breaker used to connect the primary side of the LS2100
isolation transformer to the system auxiliary bus. Depending on the application,
either the Static Starter or the Customer DCS controls this breaker and it must be
closed during starting. It may optionally be left closed after the start is complete.
The 89SS is a motor operated disconnect switch used to connect the Static Starter
load inverter output bus to the generator stator. The MarkVI controls this switch and
it must be closed during starting and opened after the start is complete.
The 52G is an optional circuit breaker used to connect the generator stator to the
system bus. The Mark VI Turbine Control controls this breaker and it must be open
during startup.
Cabinets
The enclosure is painted
ANSI-70 light gray.
The Static Starter is supplied in a factory assembled and tested, freestanding
enclosure. The isolation transformer, dc link inductor, and heat exchanger are
supplied separately from the drive enclosure. The Static Starter is supplied in a
NEMA Type 1 ventilated enclosure for indoor mounting. The enclosure has a rigid
steel frame enveloped by sheet steel with a minimum 12-gauge thickness.
Control Cabinet
The control cabinet has two front access hinged doors held in the closed position
with a three-point latch and a handle that can be padlocked. Located inside the
control cabinet are:
• Control power circuit breaker
• Control power transformer and power supply
• VME card rack
• Panel mounted relays
• I/O terminal boards
• VersaMax I/O modules
• Customer terminal boards
| TRICON 3625 TRICONEX Digital input module |
| TRICON 3503E TRICONEX Digital input module |
| TRICON 3511 TRICONEX Pulse input module |
| CI854AK01 3BSE030220R1 PROFIBUS-DP/V1 interface |
| LDGRB-01 3BSE013177R1 I/O Programmable Logic module |
| 04220FL11232A Intelligent Platforms Rxi Controller |
| V7668A-1310B0 350-9310007668-131020 D Single Board Computer |
| V7668A-131000 350-9310007668-131000 B Single Board Computer |
| IC752SPL013-BA EX2100 excitation control panel |
| C200/10/1/1/1/00 Servo controller |
| PCIE-1427 An image capture card |
| IC693CPU364 Series 90-30 Processor module |
| IC693PWR330 High Capacity Power Supply module |
| V7668A-1310B0 350-9310007668-131020 Single Board Computer |
| SST-PB3-VME-2-E SST-PB3-VME-1 interface cards |
| XVR19 6U-VME-SBC Rugged single board computer with Intel Xeon E3-1505M v6 processor |
| 3500/40-03-00 176449-01 Proximitor Monitor Bently Nevada |
| 3500/33-01-00 149986-01 Bently Nevada 16-Channel Relay Module |
| 2711P-RDT10C PanelView Plus Graphic Terminals |
| 810-048219-015 LAM Circuit board module |
| AAI835-H50 Digital I/O Module for Compatible ST2 |