GE 151X1225DF01PC03RA – Power Conversion / Drive Regulation Board
GE 151X1225DF01PC03RA – Power Conversion / Drive Regulation Board
Power magnetics are used in the system to provide isolation, voltage transformation,
and impedance. These include:
The isolation transformer feeds 3-phase ac input power to the Static Starter power
converters. The transformer provides isolation from the ac system bus and provides
the correct voltage and phasing to the static converters.
Optional ac line reactors are
available.
The dc link reactor is an air core inductor that provides inductance to smooth the
current delivered by the static power converters.
Various circuit breakers and motor operated disconnect switches are used in the
system to make the appropriate power connects required for a static start operation.
The 52SS is a circuit breaker used to connect the primary side of the LS2100
isolation transformer to the system auxiliary bus. Depending on the application,
either the Static Starter or the Customer DCS controls this breaker and it must be
closed during starting. It may optionally be left closed after the start is complete.
The 89SS is a motor operated disconnect switch used to connect the Static Starter
load inverter output bus to the generator stator. The MarkVI controls this switch and
it must be closed during starting and opened after the start is complete.
The 52G is an optional circuit breaker used to connect the generator stator to the
system bus. The Mark VI Turbine Control controls this breaker and it must be open
during startup.
Cabinets
The enclosure is painted
ANSI-70 light gray.
The Static Starter is supplied in a factory assembled and tested, freestanding
enclosure. The isolation transformer, dc link inductor, and heat exchanger are
supplied separately from the drive enclosure. The Static Starter is supplied in a
NEMA Type 1 ventilated enclosure for indoor mounting. The enclosure has a rigid
steel frame enveloped by sheet steel with a minimum 12-gauge thickness.
Control Cabinet
The control cabinet has two front access hinged doors held in the closed position
with a three-point latch and a handle that can be padlocked. Located inside the
control cabinet are:
• Control power circuit breaker
• Control power transformer and power supply
• VME card rack
• Panel mounted relays
• I/O terminal boards
• VersaMax I/O modules
• Customer terminal boards
| UAD155A0111 Excitation controller |
| PCD237A101 PEC80-CCM Static excitation system |
| MVR1600-4601 Air Cooled Rectifier Module |
| 3BHE046836R0102 GFD563A102 AC 800PEC system excitation controller |
| S-093H 3BHB030478R0009 Phase module |
| S-113N 3BHB018008R0001 Phase module |
| GFD563 AC 800PEC Controller |
| PPD513A24-110110 AC 800PEC Controller |
| VMIVME-2540 Intelligent Counter/Controller |
| TVME200-10 6U VMEbus Carrier for up to 4 singlesize or 2 double-size IndustryPack (IP) modules |
| VMIVME-3122 High-Performance 16-Bit Analog-to-Digital Converter (ADC) |
| PPC322BE1 HIEE300900R1 Industrial drive function module |
| IC697CMM742-DC Ethernet Interface Communications Modules |
| SCYC55830 58063282A Trigger plate |
| S72402-NANANA S700 digital servo drive |
| KJ4002X1-BA1 Left 8 Wide Vertical Carrier |
| 2MLR-CPUH/T MasterLogic Programmable Logic Controller |
| 5X00226G02 Ovation Westinghouse Controller module |
| TRICON 3805E TRICONEX Analog Output Modules |
| 489-P5-LO-A20 generator management relay |
| 5X00241G02 Ovation Westinghouse Controller module |
| 1X00416H01 POWER SUPPLY 24V 300W & 25V 500W OUT DIN-RAIL MOUNT |
| VT-HNC100-1-23/W-08-0-0 R900955334 VT-HNC100 Digital Axis Controllers |
| D674A906U01 Cartridge U-high HART |