the generator field current as the feedback input. While it does regulate constant field

current over varying field temperature, GE has not selected the FCR as its standard

manual regulator because it inhibits the signal independence from the over excitation

limiter.

Manual Regulator Reference (MANUAL REF) generates the manual setpoint

variable for the manual voltage regulator (MVR). Operator commands, (raise and lower

inputs) come in from direct inputs or over a data link from an HMI operator station or

from a plant DCS or remote dispatch system.

Manual Restrictive Limiter limits the under-excited operation of the EX2100e

while the manual regulator is selected (FVR or FCR). It also does not allow the manual

regulator to track the automatic regulator when the unit is operating below the field

voltage limit called for by the manual restrictive limiter.

Overexcitation Limiter (OEL) and Offline Overexcitation Protection

(OLOT) protect the generator field from damage by events that require abnormally high

field currents. These high currents, over an extended time, can overheat the field and

cause damage. Generator fields are designed to ANSI standard C50.13. which specifies

the overvoltage as a function of time that the field is designed to follow. This standard

uses curves to describe the field overheating as a function of time and current.

Potential Transformer Fuse Failure Detection (PTFD) detects loss of PT

feedback voltage to the voltage regulator. If the sensing voltage is lost or if it is

single-phased, there is a transfer to the manual regulator and an alarm output is provided.

Power System Stabilizer (PSS) provides an additional input to the automatic

regulator to improve power system dynamic performance. The PSS offered in the

EX2100e control is a multi-input system using a combination of synchronous machine

electrical power and internal frequency (which approximates rotor speed) to arrive at a

signal proportional to rotor speed. This comes from the integral of accelerating power, but

with shaft torsional signals greatly attenuated.

Reactive Current Compensation (RCC/Line Drop) has two modes: RCC and

Line Drop. The RCC mode permits sharing reactive current between paralleled machines.

Line Drop mode allows for better regulation of voltage at some point down stream from

the generator terminals.

Stator Current Limit (SCL) determines the AVR/VAR control. When the generator

stator current exceeds the rated value, the exciter changes from AVR control to a VAR

control preset. Once the stator current is less than the rated value, the exciter returns to

AVRcontrol

3500/50 288062-02   Tachometer Module
05701-A-0145 Four Channel Control Card 4   20mA Input
PCI-6251 779070-01 Multifunction DAQ   Board
PCI-6229 779068-01 Multifunction DAQ
AIP831-101 Operation Keyboard for   Eight-loop
IPM2-P0904HA I/A Series Industrial Power   Module
VME172PA644SE MVME172P4 series VME   embedded controller
GHR9010100R0002 PLCs/Machine Control
330710-000-60-10-02-00 Bentley axial   displacement probe
3150-MCM Modbus communication module
PXI-8423 Isolated 2-Port RS485 Interface   for PXI
CC-IP0101 C Series I/O is an Input/Output   system
3500/70M 140734-09 Recip Impulse Velocity   Monitor
XV-440-10TVB-1-10 Touch screen   professional parameters
3500/42M 176449-02 Proximitor Seismic   Monitor
5SHY3545L0010 Dc speed regulating medium   pressure plate
8237-2597 ProTech-GII is a configurable   overspeed
5SHY4045L0001 High voltage inverter   module
3BHB016120R0002 High voltage inverter   module
3BSE080239R1 Redundant Network Routing   Protocol (RNRP) NE870
5SHY4045L0004 Dc speed regulating medium   pressure plate 3BHB021400R0002
IS200JPDFG1AED POWER DISTRIBUTION BOARD
PFCL201CE 20KN Pillow tensiometer head
IS200JPDFG2AED 125VDC Power Distribution   Board
PXIE-1095 783882-01 high-quality device