AMAT 0100-00162 | VME Dual Channel Serial Communication Board
AMAT 0100-00162 | VME Dual Channel Serial Communication Board
Introduction
The AMAT 0100-00162 is a specialized Dual Channel Serial Communication Board manufactured by Applied Materials.
Designed for the VME (Versa Module Europa) bus architecture, this board acts as the critical data link between the system’s main controller and external peripheral devices.
It is a core component in the electronics rack of AMAT Centura, Endura, and P5000 systems, facilitating high-speed, reliable communication with subsystems such as RF generators, heat exchange controllers, and remote gas panels.
Technical Parameter Table
| Attribute | Specification |
| Manufacturer | Applied Materials (AMAT) |
| Model Number | 0100-00162 |
| Component Type | Printed Wiring Board (PWB) / Comm. Controller |
| Bus Interface | VME Bus Standard |
| Channels | Dual Independent Serial Ports (RS-232 / RS-422) |
| Compatibility | AMAT P5000, Centura 5200, Endura 5500 |
| Data Rate | High-speed asynchronous transmission |
| Weight | 0.46 kg (approx. 1.01 lbs) |
| Dimensions | 160mm x 233mm (Standard VME Card) |
| Power Requirements | +5V, +/-12V (Sourced from Backplane) |
Unique Product Description
The AMAT 0100-00162 is engineered to maintain data integrity in the high-noise environments of semiconductor fabrication.
While standard serial cards may suffer from packet loss due to electromagnetic interference (EMI) from plasma sources, the 0100-00162 features enhanced signal conditioning and optical isolation on its communication lines.
This ensures that command strings sent to critical subsystems—like a temperature setpoint to a chiller or a power level to an RF match—are received without corruption.
Its dual-channel design allows for the consolidation of multiple peripheral links onto a single VME slot, optimizing space within the system controller’s card cage.
Product Advantages and Features
Dual-Channel Versatility: Operates two independent serial links simultaneously, reducing the need for multiple communication cards.
EMI Resilience: Built-in filtering and shielded circuitry specifically designed for the RF-heavy environment of etch and deposition tools.
Seamless Bus Integration: Fully compliant with AMAT’s VME backplane protocols for immediate recognition by the system software.
Reliable Handshaking: Supports advanced hardware and software flow control to prevent data buffer overflows during high-traffic sequences.
Industrial Durability: Features high-grade components capable of sustained 24/7 operation in cleanroom environments.
Related Models
AMAT 0100-00001: Master CPU Controller Board.
AMAT 0100-00005: High-speed Serial Interface Board.
AMAT 0100-00137: Stepper Motor Controller Interface.
AMAT 0190-01121: Serial signal breakout cable assembly.
| ALSTOM | N895314513L |
| ALSTOM | N895313512X |
| ALSTOM | SDK-C0147 12004-101-00 SBS04M17C |
| ALSTOM | TRVC062105000 TRVC070938000 TRVC070938005.A |
| ALSTOM | NRD108033 8RDC44667G01 SA44667.C |
| ALSTOM | N897092520B N897092057Y TRENO N897092500E |
| ALSTOM | NRD108034 8RDB44674G01 SA44674.C |
| ALSTOM | NRD108028 8RDB43655 SA43655.E |
| ALSTOM | CMU 42015-115-00 |
| ALSTOM | N897066510E N897066010M AOVD N897066000A |
| ALSTOM | N897163510Q N897163050Q MODEM N897163100U |
| ALSTOM | 730475-D ELEMENTS-F2 |
| ALSTOM | NRD109475 8RDA44670G01 SA44670.E |
| ALSTOM | MLU VER.A01 |
| ALSTOM | N895600512D N895600051C ECPU_1 N895600200Q |
| ALSTOM | N895609510K N895609010R E32OUT N895609100P |
| ALSTOM | N897093511D N897093051D DIAGNOSTICA N897093400H |
| ALSTOM | 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 |
| ALSTOM | SDK-C0148 12003-101-01 SBS05M09B |
Other Models in the Same Series
The 0100-xxxxx series includes a wide variety of interface and logic boards:
0100-00161: Quad-channel serial interface variant.
0100-00202: Advanced motion control board.
0100-01051: Single Board Computer (SBC) module.
0100-20161: Digital I/O Expansion PWB.
Application Cases
RF Generator Control: Providing the communication link to adjust power levels and monitor reflected power in real-time.
Heat Exchanger Interface: Sending and receiving status data from the system’s Neslab or Edwards chiller units.
Remote Gas Panel Communication: Coordinating gas flow sequences with external valve manifolds and MFC controllers.
Installation and Maintenance
Installation:
ESD Protection: This board contains sensitive communication ICs. Always use a grounded wrist strap when handling.
Jumper Settings: Verify that the onboard jumpers for the serial standard (RS-232 vs RS-422) and VME address match the system’s specific requirements.
Physical Insertion: Use the card cage’s guide rails and injector handles to seat the board firmly; do not apply pressure directly to the electronic components.
Maintenance:
Port Inspection: Periodically check the external DB-9 or multi-pin connectors for bent pins or dust accumulation.
Loopback Testing: In case of communication errors, perform a loopback test via the system diagnostics to determine if the fault lies with the board or the external cable.
Cleaning: Use only electronic-grade isopropyl alcohol (IPA) to clean gold-plated edge connectors if oxidation is observed.