Phoenix

Phoenix 2904603 QUINT4-PS/1AC/24DC/40 – Power supply

QUINT4-PS/1AC/24DC/40 – Power supply

2904603

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/40 A

The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions.

Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface.

The unique SFB technology and preventive function monitoring of the QUINT POWER power supply increase the availability of your application.

Control input (configurable) Rem    Output power ON/OFF (SLEEP MODE)

Default    Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)

AC operation

Network type    Star network

Nominal input voltage range    100 V AC … 240 V AC

Input voltage range    100 V AC … 240 V AC -15 % … +10 %

Electric strength, max.    300 V AC 60 s

Typical national grid voltage    120 V AC

230 V AC

Voltage type of supply voltage    AC

Inrush current    typ. 12 A (at 25 °C)

Inrush current integral (I2t)    < 1 A2s

Inrush current limitation    12 A (after 1 ms)

Frequency range (fN)    50 Hz … 60 Hz -10 % … +10 %

16.7 Hz (acc. to EN 50163)

Mains buffering time    typ. 29 ms (120 V AC)

typ. 32 ms (230 V AC)

Current consumption    13.6 A (100 V AC)

10 A (120 V AC)

5.2 A (230 V AC)

5.4 A (240 V AC)

Nominal power consumption    1064 VA

Input fuse    16 A (slow-blow, internal)

Recommended breaker for input protection    16 A … 20 A (Characteristic B, C, D, K or comparable)

Discharge current to PE    < 3.5 mA

1.7 mA (264 V AC, 60 Hz)

DC operation

Nominal input voltage range    110 V DC … 250 V DC

Input voltage range    110 V DC … 250 V DC -18 % … +40 %

Voltage type of supply voltage    DC

Current consumption    12 A (110 V DC)

5 A (250 V DC)

Efficiency    typ. 94.8 % (120 V AC)

typ. 95.9 % (230 V AC)

Nominal output voltage    24 V DC

Setting range of the output voltage (USet)    24 V DC … 29.5 V DC (constant capacity)

Nominal output current (IN)    40 A

Static Boost (IStat.Boost)    45 A

Dynamic Boost (IDyn.Boost)    60 A (5 s)

Selective Fuse Breaking (ISFB)    215 A (15 ms)

Magnetic circuit breaker tripping    A1…A40 / B2…B25 / C1…C13 / Z1…Z16

Derating    > 60 °C … 70 °C (2.5 %/K)

Feedback voltage resistance    ≤ 35 V DC

Protection against overvoltage at the output (OVP)    ≤ 32 V DC

Control deviation    < 0.5 % (Static load change 10 % … 90 %)

< 1 % (Dynamic load change 10 % … 90 %, (10 Hz))

< 0.25 % (change in input voltage ±10 %)

Residual ripple    < 50 mVPP (with nominal values)

Short-circuit-proof    yes

No-load proof    yes

Output power    960 W

1080 W

1440 W

Maximum no-load power dissipation    < 4 W (120 V AC)

< 4 W (230 V AC)

Power loss nominal load max.    < 50 W (120 V AC)

< 50 W (230 V AC)

Power dissipation SLEEP MODE    < 3 W (120 V AC)

< 3 W (230 V AC)

Crest factor    typ. 1.5 (120 V AC)

typ. 1.6 (230 V AC)

Connection in parallel    yes, for redundancy and increased capacity

Connection in series    yes

Fuse protection (secondary side)    electronic

thermal-magnetic

thermal

Signal

Signal ground SGnd    Reference potential for Out1. Out2. and Rem

Signal Out 1 (configurable)

Digital    24 V DC 20 mA

Default    24 V DC 20 mA 24 V DC for UOut > 0.9 x USet

Signal Out 2 (configurable)

Digital    24 V DC 20 mA

Analog    4 mA … 20 mA ±5 % (Load ≤400 Ω)

Default    24 V DC 20 mA 24 V DC for POut < PN

Signal relay 13/14 (configurable)

Default    closed (Uout > 0.9 USet)

Digital    24 V DC 1 A

30 V AC/DC 0.5 A

Connection method    Screw connection

Conductor cross-section, rigid min.    0.2 mm²

Conductor cross-section, rigid max.    6 mm²

Conductor cross-section flexible min.    0.2 mm²

Conductor cross-section flexible max.    4 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    4 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    4 mm²

Conductor cross-section AWG min.    24

Conductor cross-section AWG max.    10

Stripping length    8 mm

Tightening torque, min    0.5 Nm

Tightening torque max    0.6 Nm

Output

Connection method    Screw connection

Conductor cross-section, rigid min.    0.5 mm²

Conductor cross-section, rigid max.    16 mm²

Conductor cross-section flexible min.    0.5 mm²

Conductor cross-section flexible max.    16 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.5 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    16 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.5 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    16 mm²

Conductor cross-section AWG min.    20

Conductor cross-section AWG max.    6

Stripping length    10 mm

Tightening torque, min    1.2 Nm

Tightening torque max    1.5 Nm

Signal

Connection method    Push-in connection

Conductor cross-section, rigid min.    0.2 mm²

Conductor cross-section, rigid max.    1 mm²

Conductor cross-section flexible min.    0.2 mm²

Conductor cross-section flexible max.    1.5 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.2 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    0.75 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.2 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    1.5 mm²

Conductor cross-section AWG min.    24

Conductor cross-section AWG max.    16

Stripping length    8 mm

Types of signaling    LED

Floating signal contact

Active signal output Out1 (digital, configurable)

Active signal output Out2 (analog, configurable)

Remote contact

Signal ground SGnd

Signal output

Signal option    Output current

Output voltage

Output power

UIN input voltage OK

Operating hours

Early warning of high temperatures

OVP voltage limitation active

POut    > 100 % (LED lights up yellow, output power > 960 W)

> 75 % (LED lights up green, output power > 720 W)

> 50 % (LED lights up green, output power > 480 W)

UOut    > 0.9 x USet (LED lights up green)

< 0.9 x USet (LED flashes green)

MITSUBISHI HC-KFS23K-S49
Mitsubishi A1SJ51T64
MITSUBISHI A1S65B-S1
MITSUBISHI A1S68DAV
Mitsubishi R28TB
MITSUBISHI GU-D04
MITSUBISHI MR-S11-200-Z37
MIYACHI MA-201C
MKS 223BD-00001AAB
MKS 683B-23795
MKS T3BIB-29916
MODICON 140CRP93100
Modicon AS-B875-002
MODICON PC-L984-785
MODICON NW-BM85D002
MODICON AS-J890-002
Modicon AS-S908-120   AS-9385-002
MODICON AS-BADU-204

发表回复

您的邮箱地址不会被公开。 必填项已用 * 标注