Phoenix 2904602 QUINT4-PS/1AC/24DC/20 – Power supply

2904602  QUINT4-PS/1AC/24DC/20 – Power supply

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/20 A

The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions.

Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface.

The unique SFB technology and preventive function monitoring of the QUINT POWER power supply increase the availability of your application.

Control input (configurable) Rem    Output power ON/OFF (SLEEP MODE)

Default    Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)

AC operation

Network type    Star network

Nominal input voltage range    100 V AC … 240 V AC

Input voltage range    100 V AC … 240 V AC -15 % … +10 %

Derating    < 100 V AC (1 %/V)

Electric strength, max.    300 V AC 60 s

Typical national grid voltage    120 V AC

230 V AC

Voltage type of supply voltage    AC

Inrush current    typ. 11 A (at 25 °C)

Inrush current integral (I2t)    < 0.4 A2s

Inrush current limitation    11 A (after 1 ms)

AC frequency range    50 Hz … 60 Hz -10 % … +10 %

Frequency range (fN)    50 Hz … 60 Hz -10 % … +10 %

16.7 Hz (acc. to EN 50163)

Mains buffering time    typ. 28 ms (120 V AC)

typ. 29 ms (230 V AC)

Current consumption    6.8 A (100 V AC)

5.5 A (120 V AC)

2.8 A (230 V AC)

2.7 A (240 V AC)

Nominal power consumption    520 VA

Protective circuit    Transient surge protection; Varistor, gas-filled surge arrester

Power factor (cos phi)    0.98

Switch-on time    < 1 s

Typical response time    300 ms (from SLEEP MODE)

Input fuse    12 A (slow-blow, internal)

Recommended breaker for input protection    10 A … 16 A (Characteristic B, C, D, K or comparable)

Discharge current to PE    < 3.5 mA

1.7 mA (264 V AC, 60 Hz)

DC operation

Nominal input voltage range    110 V DC … 250 V DC

Input voltage range    110 V DC … 250 V DC -18 % … +40 %

Derating    < 110 V DC (1 %/V)

Voltage type of supply voltage    DC

Current consumption    6 A (110 V DC)

2.5 A (250 V DC)

Efficiency    typ. 92.4 % (120 V AC)

typ. 94 % (230 V AC)

Output characteristic    U/I Advanced

Smart HICCUP

FUSE MODE

Nominal output voltage    24 V DC

Setting range of the output voltage (USet)    24 V DC … 29.5 V DC (constant capacity)

Nominal output current (IN)    20 A

Static Boost (IStat.Boost)    25 A

Dynamic Boost (IDyn.Boost)    30 A (5 s)

Selective Fuse Breaking (ISFB)    120 A (15 ms)

Magnetic circuit breaker tripping    A1…A16 / B2…B13 / C1…C6 / Z1…Z16

Derating    > 60 °C … 70 °C (2.5 %/K)

Feedback voltage resistance    ≤ 35 V DC

Protection against overvoltage at the output (OVP)    ≤ 32 V DC

Control deviation    < 0.5 % (Static load change 10 % … 90 %)

< 4 % (Dynamic load change 10 % … 90 %, (10 Hz))

< 0.25 % (change in input voltage ±10 %)

Residual ripple    < 50 mVPP (with nominal values)

Short-circuit-proof    yes

No-load proof    yes

Output power    480 W

600 W

720 W

2904602

Apparent power    660 VA (120 V, UOUT = 24 V, IOUT = stat. Boost)

644 VA (230 V, UOUT = 24 V, IOUT = stat. Boost)

Maximum no-load power dissipation    < 5 W (120 V AC)

< 5 W (230 V AC)

Power loss nominal load max.    < 40 W (120 V AC)

< 32 W (230 V AC)

Power dissipation SLEEP MODE    < 5 W (120 V AC)

< 5 W (230 V AC)

Crest factor    typ. 1.55 (120 V AC)

typ. 1.65 (230 V AC)

Rise time    < 1 s (UOut = 10 % … 90 %)

Connection in parallel    yes, for redundancy and increased capacity

Connection in series    yes

Fuse protection (secondary side)    electronic

thermal-magnetic

thermal

Signal

Signal ground SGnd    Reference potential for Out1. Out2. and Rem

Signal Out 1 (configurable)

Digital    24 V DC 20 mA

Default    24 V DC 20 mA 24 V DC for UOut > 0.9 x USet

Signal Out 2 (configurable)

Digital    24 V DC 20 mA

Analog    4 mA … 20 mA ±5 % (Load ≤400 Ω)

Default    24 V DC 20 mA 24 V DC for POut < PN

Signal relay 13/14 (configurable)

Default    closed (Uout > 0.9 USet)

Digital    24 V DC 1 A

30 V AC/DC 0.5 A

Input

Connection method    Screw connection

Conductor cross-section, rigid min.    0.2 mm²

Conductor cross-section, rigid max.    6 mm²

Conductor cross-section flexible min.    0.2 mm²

Conductor cross-section flexible max.    4 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    4 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    4 mm²

Conductor cross-section AWG min.    24

Conductor cross-section AWG max.    10

Stripping length    8 mm

Tightening torque, min    0.5 Nm

Tightening torque max    0.6 Nm

Output

Connection method    Screw connection

Conductor cross-section, rigid min.    0.2 mm²

Conductor cross-section, rigid max.    6 mm²

Conductor cross-section flexible min.    0.2 mm²

Conductor cross-section flexible max.    4 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    4 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.25 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    4 mm²

Conductor cross-section AWG min.    24

Conductor cross-section AWG max.    10

Stripping length    8 mm

Tightening torque, min    0.5 Nm

Tightening torque max    0.6 Nm

Signal

Connection method    Push-in connection

Conductor cross-section, rigid min.    0.2 mm²

Conductor cross-section, rigid max.    1 mm²

Conductor cross-section flexible min.    0.2 mm²

Conductor cross-section flexible max.    1.5 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, min.    0.2 mm²

Single conductor/flexible terminal point with ferrule with plastic sleeve, max.    0.75 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, min.    0.2 mm²

Single conductor/flexible terminal point with ferrule without plastic sleeve, max.    1.5 mm²

Conductor cross-section AWG min.    24

Conductor cross-section AWG max.    16

Stripping length    8 mm