GE

DS200RT8AG3AHC Relay Output Terminal Board

DS200RT8AG3AHC  Relay Output Terminal Board

GE Electric | DS200RT8AG3AHC | Relay Output Terminal Board

Product Description:

The GE DS200RT8AG3AHC is a Relay Output Terminal Board for the Mark VI gas/steam turbine control system.

It provides configurable relay outputs to interface between the controller and high-power field devices (e.g., actuators, pumps), enabling critical shutdown and safety functions in power generation applications.

Feature

Specification / Description

Manufacturer

GE Power Conversion (formerly GE Industrial Systems)

Series

Mark VI Speedtronic™ Turbine Control System

Part Number

DS200RT8AG3AHC

Board Type

Relay Output Terminal Board

Channels

8 relay channels (Form C contacts)

Contact Rating

5A @ 30VDC / 250VAC (resistive)

Max. Switching Power

62.5W DC / 1250VA AC

Contact Material

Silver Alloy (AgCdO)

Isolation Voltage

1500V AC (channel-to-channel)

Response Time

≤10 ms (operate/release)

Connection Type

Screw terminal blocks (14-22 AWG)

Status Indication

LED per channel (relay state)

Mounting

DIN rail or panel mount

Operating Temp.

-40°C to +85°C

Compliance

UL 508. CE, RoHS

 

Key Features:

Form C Contacts – SPDT (Single-Pole Double-Throw) with NO/NC options for failsafe design.

High Surge Handling | Withstands 100A inrush (10 ms) for motor/starter control.

Galvanic Isolation | 1.5kV between coils/contacts and logic circuits.

Hot-Replacement | Supports live swap in Mark VI racks without shutdown.

Diagnostic LEDs | Real-time channel status monitoring.

Redundancy Support | Compatible with dual-processor Mark VI configurations.

Primary Function & Purpose:

Acts as a high-power interface between Mark VI controllers and field devices to:

Execute turbine emergency shutdowns (ESD) and permissives.

Control auxiliary systems (lube oil pumps, cooling fans).

Trigger alarms/annunciators based on protection logic.

Typical Applications:

Turbine Protection – Trip solenoid valves on overspeed/vibration events.

Fuel Systems – Shut off gas/fluid supply valves during faults.

Generator Control – Enable/disable excitation systems.

Cooling Circuits – Start/stop auxiliary coolant pumps.

Fire Suppression – Activate deluge systems during emergencies.

Application Fields:

Critical for power generation safety systems in:

Gas Turbine Plants: GE Frame 5/6/7/9 series control cabinets.

Steam Turbines: Boiler feed pump trips, condenser vacuum protection.

Hydroelectric Plants: Gate actuator control, brake systems.

Compressor Stations: Pipeline emergency shutdown (ESD) systems.

Industrial Co-Gen: Backup generator synchronization control.

发表回复