Woodward

Woodward SPM-D2-1040B/NYB 8440-2189

Product number: 8440-2189

Manufacturer product number: 8440-2189

Description: Woodward: CONTROL-SPM-D2-1040B/NYB

SPM-D2-1145B/LSXR 8440-2169

SPM-D2-1115B/LSXR 8440-2165

Documentation: Product Spec: 37623. Manual: 37618

3 Phase Paralleling

SPM-D2-1040B/YB 8440-2176

SPM-D2-1010B/YB 8440-2167

SPM-D2-1040B/NYB 8440-2189

SPM-D2-1010B/NYB 8440-2177

Color: yellow

f+

Color: yellow

V-

Color: yellow

V+

Color: yellow

Gen CB – ON

Color: green

Bus CB – ON

here: non-functional

Color: green

Decrease frequency governor output

The “f-” LED indicates if the unit is outputting a pulse to decrease the fre

quency. The “f-” LED illuminates when the relay “speed lower” is energized.

Increase frequency governor output

The “f+” LED indicates if the unit is outputting a pulse to increase the fre

quency. The “f+” LED illuminates when the relay “speed raise” is energized.

Decrease voltage governor output

The “V-” LED indicates if the unit is outputting a pulse to decrease the volt

age. The “V-” LED illuminates when the relay “voltage lower” is energized.

Increase voltage governor output

The “V+” LED indicates if the unit is outputting a pulse to increase the volt

age. The “V+” LED illuminates when the relay “voltage raise” is energized.

Power circuit breaker ON

The “Gen CB – ON” LED indicates if the response of the power circuit break

er is open or closed. The “Gen CB – ON” LED illuminates if the discrete input

“Reply: CB is open” is not energized and will turn off as soon as the discrete

input is energized.

The LED may also be flashing if one of the following cases occurs:

 Discrete input “Reply: CB is open” is not energized and the systems U1 and

U2 are not synchronized

 Discrete input “Reply: CB is open” is energized and the systems U1 and U2

are synchronized

(The unit checks the status of the discrete input “Reply: CB is open” for plau

sibility. The unit assumes that the systems U1 and U2 are synchronized if the

switch makes contact and that the systems cannot be synchronized if the

switch breaks contact.)

Mains power circuit breaker ON

NOTE: This LED is non-functional, as this control is only designed to oper

ate one circuit breaker.

Configuration may be performed by manually inputting the desired set points utilizing the pushbuttons and the LC

display. In order to facilitate configuring the parameters, the push buttons have been enabled with an

AUTOROLL function. This permits the user to advance to the next setting, configuration screen, digit, and/or

cursor position more rapidly by pressing and holding the corresponding pushbutton.

Display / Select Display / Select

Automatic mode: Display – By pressing this button, the user may navigate

through the displayed measured parameters and alarm messag

es.

Configuration: Select – Advances the LC display to the next configuration

screen. If any values in a configuration screen have been modi

fied with the “Digit” or “Cursor”, then the “Select” button

must be pressed to save the new setting. By pressing this push

button again, the user causes the system to display the next

configuration screen.

Digit Digit 

Automatic mode: Digit – no function

Configuration: Digit – Numerical values over the cursor are increased by

one digit. The increase is restricted by the admissible limits (re

fer to the list of parameters included in the appendix). If the

maximum admissible number is reached, the number automati

cally returns to the lowest admissible number.

Clear / Cursor  Clear / Cursor

Automatic mode: Clear – Alarms that have occurred may be acknowledged

by pressing this button as long as the fault that triggered the

alarm is no longer present.

Configuration: Cursor – This button moves the cursor one position from

left to right. When the cursor is under the last digit that may be

changed, it may be moved to the first number of the value by

pressing the “Cursor” button again.