ABB

ABB 500SCM01 1MRB150004R0001 1MRB200059/C Signal Regulation and Monitoring Module

The ABB 500SCM01 (Part Number: 1MRB150004R0001 / 1MRB200059/C) is a Signal Conditioning and Monitoring (or Serial Communication/Converter) module specifically designed for the ABB REB500 busbar protection system.

It acts as a specialized interface for handling high-priority synchronization and serial data signals within the protection rack.

Introduction

The 500SCM01 is a critical utility module in the REB500 ecosystem. Its primary role is to provide a clean, isolated interface for auxiliary signals that fall outside the scope of standard binary or analog inputs.

The revision “/C” identifies this as a hardware-optimized version with improved signal filtering and electromagnetic compatibility (EMC), ensuring it can operate reliably in the electrically “noisy” environment of a high-voltage substation.

Technical Parameter Table

Parameter Specification
Model Number 500SCM01
Order Code 1MRB150004R0001
Reference Code 1MRB200059/C
Function Signal Conversion / Serial Monitoring
Power Supply 5V / 24V DC (via internal backplane)
Isolation Voltage 2.5 kV AC
Communication Ports Serial (RS232/RS485) internal/external links
Sampling Support High-speed synchronization pulse processing
Operating Temp -10°C to +55°C
Mounting 19-inch Subrack (Plug-in)

Product Advantages and Features

Advanced Signal Conditioning: Filters out high-frequency noise from field wiring, preventing “ghost” signals from reaching the CPU.

Galvanic Isolation: High insulation levels protect the central unit electronics from surges originating in the substation yard.

Precision Timing: Specifically engineered to handle time-synchronization signals (like PPS or IRIG-B) across the internal bus without significant propagation delay.

Hardware Rev /C Stability: Utilizes high-grade capacitors and industrial-strength components for a long service life (typically 20+ years).

Hot-Swap Support: In many configurations, this module can be replaced while the rack is powered (provided the proper bypass procedures are followed).

Application Cases

Distributed Busbar Protection: Used to interface synchronization links between Central Units and peripheral Bay Units.

External Logic Integration: Converting non-standard serial signals from legacy protection relays into data the REB500 bus can interpret.

Redundant Communication: Acts as a secondary data path for system-level diagnostics and monitoring.

Station Clock Interface: Serving as the physical input point for a station’s Master Clock to synchronize all protection event logs.

ABB SK616001-A
ABB F362
ABB DSQC332A
ABB DSQC633
ABB REF610
ABB 3BHB005171R0101
ABB C310/0020/STD
ABB 07KT97H3
ABB 5SHX1060H0003
ABB 216AB61
ABB 216DB61
ABB NPCT-01C
ABB 5SHY3545L0009
ABB 3HAC17484-8108
ABB PFCL201C   10KN
ABB 086345-504
ABB 086349-002
ABB 086329-003

Installation and Maintenance

Installation

Slot Alignment: The 500SCM01 must be placed in the designated slot for auxiliary/serial modules. Do not force the module; ensure the backplane pins are perfectly aligned.

ESD Safety: Always wear a grounded anti-static wrist strap. Touching the PCB components directly can cause latent damage to the CMOS chips.

Firmware Matching: Ensure the hardware revision /C is compatible with your current HMI500 configuration version.

500SCM01 1MRB200059C 1MRB15004R0001

Maintenance

Log Analysis: Periodically check the REB500 “Internal Communication” logs. Occasional retries can indicate that the SCM module is struggling with signal noise or cable degradation.

Contact Cleaning: During major maintenance cycles, inspect the backplane connector for oxidation. If necessary, use a non-residue contact cleaner.

Thermal Check: Since this module is often sandwiched between the CPU and Power Supply, ensure the rack fans are moving air effectively across the SCM surface.

Other Models in the Same Series

Model    Description

500CPU05    Central Processing Unit (The “Brain”)

500BIO01    Binary Input/Output Interface

500TRM02    Transformer Input Module (Analog signals)

500CIM05    Ethernet Communication Interface

500PSM01    Power Supply Module

Peer Tip: If you are troubleshooting a “Time Sync Lost” alarm in an REB500 system, the 500SCM01 is often the hardware interface responsible.

Check the LEDs on this module first—a steady red “Fail” light usually indicates an internal hardware fault rather than a cabling issue.